RAPID 3-DIMENSIONAL T1-WEIGHTED MR IMAGING WITH THE MP-RAGE SEQUENCE

被引:122
作者
MUGLER, JP
BROOKEMAN, JR
机构
[1] Departments of Radiology and Biomedical Engineering, University of Virginia Health Sciences Center, Charlottesville, Virginia, 22908, Box 190
来源
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING | 1991年 / 1卷 / 05期
关键词
ARTIFACT; BRAIN; MR STUDIES; IMAGE PROCESSING; MAGNETIC RESONANCE (MR); EXPERIMENTAL; MODEL; MATHEMATICAL; PULSE SEQUENCES; RAPID IMAGING; 3-DIMENSIONAL IMAGING;
D O I
10.1002/jmri.1880010509
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors investigated the application of three-dimensional (3D) magnetization-prepared rapid gradient-echo (MP-RAGE) imaging to the acquisition of small (32 x 128 x 256) T1-weighted 3D data sets with imaging times of approximately 1 minute. A theoretical model was used to study the contrast behavior of brain tissue. On the basis of these theoretical results, 3D MP-RAGE sequences were implemented on a 1.5-T whole-body imager. Thirty-two-section 3D data sets demonstrating good signal-to-noise ratios and resolution and strong T1-weighted contrast were obtained in 1 minute. Compared with standard short TR/TE spin-echo sequences with the same imaging times and comparable sequence parameters, the 3D MP-RAGE sequence delivered increases of more than 50% in the white matter/gray matter signal difference-to-noise and white matter signal-to-noise ratios, and provided almost twice as many sections. These sequences may find a clinical role in 3D scout imaging and screening and in patients with claustrophobia or trauma.
引用
收藏
页码:561 / 567
页数:7
相关论文
共 12 条
[1]  
Mugler JP, Brookeman JR, Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE), Magn Reson Med, 15, pp. 152-157, (1990)
[2]  
Haase A, Matthaei D, Bartkowski R, Duhmke E, Leibfritz D, Inversion recovery snapshot FLASH MR imaging, J Comput Assist Tomogr, 13, pp. 1036-1040, (1989)
[3]  
Haase A, Snapshot FLASH MRI: applications to T1, T2, and chemical shift imaging, Magn Reson Med, 13, pp. 77-89, (1990)
[4]  
Haase A, Frahm J, Matthaei D, Hanicke W, Merboldt K-D, FLASH imaging: rapid NMR imaging using low flip‐angle pulses, J Magn Reson, 67, pp. 258-266, (1986)
[5]  
Bottomley PA, Hardy CJ, Argersinger RE, Allen-Moore G, A review of 1H nuclear magnetic resonance relaxation in pathology: are T1 and T2 diagnostic?, Med Phys, 14, pp. 1-37, (1987)
[6]  
Brix G, Schad LR, Deimling M, Lorenz WJ, Fast and precise T1 imaging using a TOMROP sequence, Magn Reson Imaging, 8, pp. 351-356, (1990)
[7]  
Norris DG, Bottcher U, Leibfritz D, A simple method of generating variable T1 contrast images using temporally reordered phase encoding, Magn Reson Med, 15, pp. 483-490, (1990)
[8]  
Holsinger AE, Riederer SJ, The importance of phase‐encoding order in ultra‐short TR snapshot MR imaging, Magn Reson Med, 16, pp. 481-488, (1990)
[9]  
Mugler JP, Spraggins TA, Improving image quality in snapshot FLASH and 3D MP RAGE sequences by employing reordered phase encoding (abstr), Book of abstracts: Society of Magnetic Resonance in Medicine, (1990)
[10]  
Wood ML, Runge VM, Artifacts due to residual magnetization in three‐dimensional magnetic resonance imaging, Med Phys, 15, pp. 825-831, (1988)