STANDARDIZATION OF TIBIAL FRACTURES IN THE RAT

被引:32
作者
BAK, B [1 ]
JENSEN, KS [1 ]
机构
[1] TECH UNIV DENMARK,PHYS LAB 3,DK-2800 LYNGBY,DENMARK
关键词
RAT; FRACTURES; BIOMECHANICS; STANDARDIZATION;
D O I
10.1016/8756-3282(92)90073-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The influence of the fracture level on the biomechanical properties of healing rat tibial fractures has not been investigated so far, despite the widespread use of rats in fracture healing studies. Fractures were produced in four different zones in the right rat tibia and immobilized with a K-wire. A fifth group of rats was not fractured. After 40 days of healing the fractures and the non-fractured bones were tested in three-point bending. A distinct correlation was found between fracture level and mechanical parameters: maximum load, maximum stiffness, and maximum stress decreased the more distal the fracture was located. In the non-fractured bones, maximum load and maximum stress were constant in all four zones tested, whereas energy absorption increased in the distal part of the tibia. No influence of the healing fracture was found on the contralateral, non-fractured tibia, compared with the animals left undisturbed, and the mechanical properties of the right and the left tibia were found to be symmetrical in terms of mean values. Four different methods of determining the area moment of inertia were investigated, and the simple method of approximating the cross section to an elliptical annulus was found to correlate well with the area moment of inertia, determined from computer tracings of bone slices prepared from the test specimens after the bending test. The computer tracings were corrected for the compression of the specimens caused by the mechanical test.
引用
收藏
页码:289 / 295
页数:7
相关论文
共 17 条
[1]   REDUCED ENERGY-ABSORPTION OF HEALED FRACTURE IN THE RAT [J].
BAK, B ;
ANDREASSEN, TT .
ACTA ORTHOPAEDICA SCANDINAVICA, 1988, 59 (05) :548-551
[2]   INCREASED MECHANICAL STRENGTH OF HEALING RAT TIBIAL FRACTURES TREATED WITH BIOSYNTHETIC HUMAN GROWTH-HORMONE [J].
BAK, B ;
JORGENSEN, PH ;
ANDREASSEN, TT .
BONE, 1990, 11 (04) :233-239
[3]  
BONNARENS F, 1984, Journal of Orthopaedic Research, V2, P97, DOI 10.1002/jor.1100020115
[4]   ULTIMATE PROPERTIES OF BONE TISSUE - EFFECTS OF YIELDING [J].
BURSTEIN, AH ;
FRANKEL, VH ;
CURREY, JD ;
REILLY, DT .
JOURNAL OF BIOMECHANICS, 1972, 5 (01) :35-&
[5]   STANDARD TEST FOR LABORATORY ANIMAL BONE [J].
BURSTEIN, AH ;
FRANKEL, VH .
JOURNAL OF BIOMECHANICS, 1971, 4 (02) :155-&
[6]  
CHAO EYS, 1989, CLIN ORTHOPAEDICS, V241, P24
[7]   THE EFFECTS OF DRYING AND RE-WETTING ON SOME MECHANICAL-PROPERTIES OF CORTICAL BONE [J].
CURREY, JD .
JOURNAL OF BIOMECHANICS, 1988, 21 (05) :439-441
[8]   MECHANICAL-PROPERTIES OF FRACTURED AND INTACT RAT FEMORA EVALUATED BY BENDING, TORSIONAL AND TENSILE TESTS [J].
EKELAND, A ;
ENGESAETER, LB ;
LANGELAND, N .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (06) :605-613
[9]  
ENGESAETER LB, 1978, ACTA CHIR SCAND S487, V145, P15
[10]  
Frost H M, 1983, Henry Ford Hosp Med J, V31, P3