REGURGITANT FLOW IN CARDIAC-VALVE PROSTHESES - DIAGNOSTIC-VALUE OF GRADIENT ECHO NUCLEAR-MAGNETIC-RESONANCE IMAGING IN REFERENCE TO TRANSESOPHAGEAL 2-DIMENSIONAL COLOR DOPPLER ECHOCARDIOGRAPHY

被引:21
作者
DEUTSCH, HJ
BACHMANN, R
SECHTEM, U
CURTIUS, JM
JUNGEHULSING, M
SCHICHA, H
HILGER, HH
机构
[1] UNIV COLOGNE,INNERE MED KLIN 3,JOSEPH STELZMANN STR 9,W-5000 COLOGNE 41,GERMANY
[2] UNIV COLOGNE,NUKL MED KLIN & POLIKLIN,W-5000 COLOGNE 41,GERMANY
关键词
D O I
10.1016/0735-1097(92)90610-Y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Gradient echo nuclear magnetic resonance (NMR) imaging and transesophageal two-dimensional color Doppler echocardiography are flow-sensitive techniques that have been used in the diagnosis and grading of valvular regurgitation. To define the diagnostic value of gradient echo NMR imaging in the detection of regurgitant flow in cardiac valve prostheses and the differentiation of physiologic leakage flow from pathologic transvalvular or paravalvular leakage flow, 47 patients with 55 valve prostheses were examined. Color Doppler transesophageal echocardiography was used for comparison. Surgical confirmation of findings was obtained in 11 patients with 13 valve prostheses. Gradient echo NMR imaging showed regurgitant flow in 37 of 43 valves with a jet seen on transesophageal echocardiography and it detected physiologic leakage flow in 4 additional valves. There was 96% agreement between the two methods in distinguishing between physiologic and pathologic leakage flow. The methods differed on jet origin of pathologic leakage flow in six prostheses. The degree of regurgitation was graded by both NMR imaging and transesophageal echocardiography, according to the area of the regurgitant jet visualized; gradings were identical for 75% of valve prostheses. Quantification of jet length and area showed a good correlation between the two methods (r = 0.85 and r = 0.91, respectively). Gradient echo NMR imaging is a useful noninvasive technique for the detection, localization and estimation of regurgitant flow in cardiac valve prostheses. However, because transesophageal echocardiography is less time-consuming and less expensive, gradient echo NMR imaging is unlikely to displace transesophageal echocardiography and should be used only in the occasional patient who cannot be adequately imaged by echocardiography.
引用
收藏
页码:1500 / 1507
页数:8
相关论文
共 22 条
[1]   BIPLANE TRANSESOPHAGEAL ECHOCARDIOGRAPHY - ANATOMICAL ORIENTATION AND SUGGESTIONS FOR STANDARD PLANES [J].
CURTIUS, JM ;
LEISCHIK, R ;
ARNOLD, G ;
SANDER, C ;
DEUTSCH, HJ .
AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (02) :65-71
[2]  
Daniel L B, 1990, Echocardiography, V7, P83, DOI 10.1111/j.1540-8175.1990.tb00352.x
[3]   A CARDIAC PHANTOM AND PULSATILE FLOW PUMP FOR MAGNETIC-RESONANCE IMAGING STUDIES [J].
EVANS, AJ ;
HEDLUND, LW ;
HERFKENS, RJ .
INVESTIGATIVE RADIOLOGY, 1988, 23 (08) :579-583
[4]   INVITRO EVALUATION OF 6 MECHANICAL AND 6 BIOPROSTHETIC VALVES [J].
FISHER, J ;
REECE, IJ ;
WHEATLEY, DJ .
THORACIC AND CARDIOVASCULAR SURGEON, 1986, 34 (03) :157-162
[5]   DOPPLER COLOR FLOW MAPPING IN THE EVALUATION OF PROSTHETIC MITRAL AND AORTIC-VALVE FUNCTION [J].
KAPUR, KK ;
FAN, P ;
NANDA, NC ;
YOGANATHAN, AP ;
GOYAL, RG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (07) :1561-1571
[6]   VALUE AND LIMITATIONS OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN ASSESSMENT OF MITRAL-VALVE PROSTHESES [J].
KHANDHERIA, BK ;
SEWARD, JB ;
OH, JK ;
FREEMAN, WK ;
NICHOLS, BA ;
SINAK, LJ ;
MILLER, FA ;
TAJIK, AJ .
CIRCULATION, 1991, 83 (06) :1956-1968
[7]  
Mohr-Kahaly S, 1990, J Am Soc Echocardiogr, V3, P187
[8]  
MOHRKAHALY S, 1989, TRANSESOPHAGEAL ECHO, P183
[9]   TRANS-ESOPHAGEAL TWO-DIMENSIONAL ECHOCARDIOGRAPHY AND COLOR DOPPLER FLOW VELOCITY MAPPING IN THE EVALUATION OF CARDIAC-VALVE PROSTHESES [J].
NELLESSEN, U ;
SCHNITTGER, I ;
APPLETON, CP ;
MASUYAMA, T ;
BOLGER, A ;
FISCHELL, TA ;
TYE, T ;
POPP, RL .
CIRCULATION, 1988, 78 (04) :848-855
[10]   CINE MR IMAGING IN MITRAL REGURGITATION - COMPARISON WITH COLOR DOPPLER FLOW IMAGING [J].
NISHIMURA, T ;
YAMADA, N ;
ITOH, A ;
MIYATAKE, K .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (04) :721-724