THE RELATIONSHIP BETWEEN DIALYSIS GRAFT PRESSURE AND STENOSIS

被引:28
作者
SULLIVAN, KL
BESARAB, A
DORRELL, S
MORITZ, MJ
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DEPT MED,PHILADELPHIA,PA 19107
[2] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DEPT SURG,PHILADELPHIA,PA 19107
关键词
DIALYSIS; FISTULA; GRAFT; HEMODYNAMIC ASSESSMENT; STENOSIS;
D O I
10.1097/00004424-199205000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. Pressure measurements during dialysis have been used to screen for venous outlet stenosis, but the relationship between the degree of stenosis and pressure has not been defined. METHODS. To determine this relationship, failing or failed dialysis grafts (n = 34) were studied with angiography and pressure measurements from the segment of the graft near the arterial anastomosis. RESULTS. By linear regression, the relationship between the highest grade stenosis in or central to the graft and pressure was as follows: percent stenosis = 55 systolic graft pressure/systolic blood pressure + 13 (r = 0.75). CONCLUSIONS. There is a positive correlation between the severity of stenosis and graft pressure, confirming the use of this measurement in screening for stenosis. It is hypothesized that this relationship is the result of progressive elimination of the normal pressure drop between the artery and arterial limb of the graft as the degree of stenosis increases.
引用
收藏
页码:352 / 355
页数:4
相关论文
共 8 条
[1]  
Besarab A, 1991, ASAIO Trans, V37, pM270
[2]   THE ROLE OF PERCUTANEOUS ANGIOPLASTY IN THE MANAGEMENT OF CHRONIC-HEMODIALYSIS FISTULAS [J].
GLANZ, S ;
GORDON, DH ;
BUTT, KMH ;
HONG, J ;
LIPKOWITZ, GS .
ANNALS OF SURGERY, 1987, 206 (06) :777-781
[3]   AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD [J].
MANCINI, GBJ ;
SIMON, SB ;
MCGILLEM, MJ ;
LEFREE, MT ;
FRIEDMAN, HZ ;
VOGEL, RA .
CIRCULATION, 1987, 75 (02) :452-460
[4]   NONINVASIVE BLOOD-FLOW MEASUREMENT IN EXPANDED POLYTETRAFLUOROETHYLENE GRAFTS FOR HEMODIALYSIS ACCESS [J].
RITTGERS, SE ;
GARCIAVALDEZ, C ;
MCCORMICK, JT ;
POSNER, MP .
JOURNAL OF VASCULAR SURGERY, 1986, 3 (04) :635-642
[5]   PREVENTION OF HEMODIALYSIS FISTULA THROMBOSIS - EARLY DETECTION OF VENOUS STENOSES [J].
SCHWAB, SJ ;
RAYMOND, JR ;
SAEED, M ;
NEWMAN, GE ;
DENNIS, PA ;
BOLLINGER, RR .
KIDNEY INTERNATIONAL, 1989, 36 (04) :707-711
[6]   OPTIMIZATION OF HIGH-EFFICIENCY HEMODIALYSIS BY DETECTION AND CORRECTION OF FISTULA DYSFUNCTION [J].
WINDUS, DW ;
AUDRAIN, J ;
VANDERSON, R ;
JENDRISAK, MD ;
PICUS, D ;
DELMEZ, JA .
KIDNEY INTERNATIONAL, 1990, 38 (02) :337-341
[7]  
ZAMORA JL, 1985, ASAIO T, V31, P119
[8]  
ZIBARI GB, 1988, SURGERY, V104, P681