SILICONE BREAST IMPLANT RUPTURE - COMPARISON BETWEEN 3-POINT DIXON AND FAST SPIN-ECHO NIR IMAGING

被引:40
作者
GORCZYCA, DP
SCHNEIDER, E
DEBRUHL, ND
FOO, TKF
AHN, CY
SAYRE, JW
SHAW, WW
BASSETT, LW
机构
[1] GE CO,MED SYST,MILWAUKEE,WI 53188
[2] UNIV CALIF LOS ANGELES,SCH MED,JONSSON COMPREHENS CANC CTR,LOS ANGELES,CA 90024
关键词
D O I
10.2214/ajr.162.2.8310916
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. This study was designed to compare the three-point Dixon technique with our present MR protocol incorporating T2-weighted fast spin echo and fast spin echo with water suppression to detect ruptured silicone breast implants. SUBJECTS AND METHODS. Eighty-two symptomatic women with silicone breast implants were examined with both the three-point Dixon technique and fast spin-echo MR sequences. Of these patients, 41 had surgery to remove their implants. Four radiologists reviewed the images from only those patients who had surgery and graded each for rupture by using a scale of 1-5. Receiver-operating-characteristic analysis was performed. RESULTS. Of 81 implants removed, 18 were ruptured. Silicone implant ruptures were identified more frequently on the fast spin-echo sequence than on the three-point Dixon sequence, with areas under the ROC curves of .95 and .84, respectively. Although the difference was not statistically significant, the sensitivity for detecting silicone implant rupture was 89% for the fast spin-echo sequence and 61% for the three-point Dixon sequence. The specificity was 97% for both sequences. CONCLUSION. Silicone implant ruptures were detected more frequently with fast spin-echo MR sequences than with the three-point Dixon technique, although the difference was not significant. The greater spatial resolution used for the fast spin-echo sequence partially accounts for the difference in detection of implant ruptures in this study.
引用
收藏
页码:305 / 310
页数:6
相关论文
共 18 条
[1]   MEASURING OBSERVER PERFORMANCE BY ROC ANALYSIS - INDICATIONS AND COMPLICATIONS [J].
BERBAUM, KS ;
DORFMAN, DD ;
FRANKEN, EA .
INVESTIGATIVE RADIOLOGY, 1989, 24 (03) :228-233
[2]   BREAST AUGMENTATION - A RISK FACTOR FOR BREAST-CANCER [J].
BERKEL, H ;
BIRDSELL, DC ;
JENKINS, H .
NEW ENGLAND JOURNAL OF MEDICINE, 1992, 326 (25) :1649-1653
[3]   FACT AND FICTION ABOUT BREAST IMPLANT BLEED [J].
BRODY, GS .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1977, 60 (04) :615-616
[4]  
CRONIN TD, 1964, 3RD T INT C PLAST SU
[5]   MAXIMUM-LIKELIHOOD ESTIMATION OF PARAMETERS OF SIGNAL-DETECTION THEORY AND DETERMINATION OF CONFIDENCE INTERVALS - RATING-METHOD DATA [J].
DORFMAN, DD ;
ALF, E .
JOURNAL OF MATHEMATICAL PSYCHOLOGY, 1969, 6 (03) :487-&
[6]   RECEIVER OPERATING CHARACTERISTIC RATING ANALYSIS - GENERALIZATION TO THE POPULATION OF READERS AND PATIENTS WITH THE JACKKNIFE METHOD [J].
DORFMAN, DD ;
BERBAUM, KS ;
METZ, CE .
INVESTIGATIVE RADIOLOGY, 1992, 27 (09) :723-731
[7]   AUGMENTATION MAMMAPALSTY - NORMAL AND ABNORMAL FINDINGS WITH MAMMOGRAPHY AND ULTRASOUND [J].
GANOTT, MA ;
HARRIS, KM ;
ILKHANIPOUR, ZS ;
COSTAGRECO, MA .
RADIOGRAPHICS, 1992, 12 (02) :281-295
[8]   3-POINT DIXON TECHNIQUE FOR TRUE WATER FAT DECOMPOSITION WITH BO INHOMOGENEITY CORRECTION [J].
GLOVER, GH ;
SCHNEIDER, E .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :371-383
[9]  
GLOVER GH, 1992, MAGN RESON IMAGING, V1, P521
[10]   SILICONE BREAST IMPLANTS INVIVO - MR IMAGING [J].
GORCZYCA, DP ;
SINHA, S ;
AHN, CY ;
DEBRUHL, ND ;
HAYES, MK ;
GAUSCHE, VR ;
SHAW, WW ;
BASSETT, LW .
RADIOLOGY, 1992, 185 (02) :407-410