LONG-TERM EFFICACY OF AN ANTITACHYCARDIA PACEMAKER AND IMPLANTABLE DEFIBRILLATOR COMBINATION

被引:7
作者
BONNET, CA
FOGOROS, RN
ELSON, JJ
FIEDLER, SB
BURKHOLDER, JA
机构
[1] Division of Cardiology, Allegheny General Hospital, Medical College of Pennsylvania, Pittsburgh, Pennsylvania
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1991年 / 14卷 / 05期
关键词
ANTITACHYCARDIA PACEMAKER; IMPLANTABLE DEFIBRILLATOR; VENTRICULAR TACHYCARDIA;
D O I
10.1111/j.1540-8159.1991.tb04112.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Antitachycardia pacemakers and implantable cardioverter defibrillators (ICD) were implanted in 14 patients to control recurrent hemodynamically stable ventricular tachycardia (VT). All patients underwent extensive preimplant testing in the electrophysiology laboratory documenting that in each patient at least 50 episodes of VT could be reliably terminated by an external model of the antitachycardia pacemaker. The burst scanning mode of antitachycardia pacing was used in all patients. ICDs were implanted solely as a back up should acceleration of VT occur, and all had high nonprogrammable rate cutoffs (mean 191 +/- 12 beats/min). During a mean follow-up of 25 +/- 6 months, 6,029 episodes of VT were treated in the 14 patients. Only 103 ICD discharges were required (approximately one discharge per 60 episodes of VT). Ten of the 14 patients received discharges from their ICDs. No deaths have occurred. All devices remain active and in the automatic mode. Thus, an antitachycardia pacemaker and ICD combination can safely and effectively terminate VT in highly selected patients who are subjected to extensive preimplant testing. In such patients, the vast majority of episodes of VT can be terminated with antitachycardia pacing, and only rarely is a discharge required from the ICD.
引用
收藏
页码:814 / 822
页数:9
相关论文
共 17 条
[1]   INFLUENCE OF VENTRICULAR-FIBRILLATION DURATION ON DEFIBRILLATION ENERGY IN DOGS USING BIDIRECTIONAL PULSE DISCHARGES [J].
ECHT, DS ;
BARBEY, JT ;
BLACK, JN .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (09) :1315-1323
[2]   PACING FOR VENTRICULAR-TACHYCARDIA [J].
FISHER, JD ;
KIM, SG ;
MATOS, JA ;
WASPE, LE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06) :1278-1290
[3]   IMPLANTABLE PACERS FOR TACHYCARDIA TERMINATION - STIMULATION TECHNIQUES AND LONG-TERM EFFICACY [J].
FISHER, JD ;
JOHNSTON, DR ;
KIM, SG ;
FURMAN, S ;
MERCANDO, AM .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1325-1333
[4]   TERMINATION OF VENTRICULAR TACHYCARDIA WITH BURSTS OF RAPID VENTRICULAR PACING [J].
FISHER, JD ;
MEHRA, R ;
FURMAN, S .
AMERICAN JOURNAL OF CARDIOLOGY, 1978, 41 (01) :94-102
[5]   ELECTRICAL DEVICES FOR TREATMENT OF ARRHYTHMIAS [J].
FISHER, JD ;
KIM, SG ;
MERCANDO, AD .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (02) :A45-A60
[6]   THE AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IN DRUG-REFRACTORY VENTRICULAR TACHYARRHYTHMIAS [J].
FOGOROS, RN ;
FIEDLER, SB ;
ELSON, JJ .
ANNALS OF INTERNAL MEDICINE, 1987, 107 (05) :635-641
[7]   TERMINATION OF MALIGNANT VENTRICULAR TACHYCARDIAS BY USE OF AN AUTOMATICAL DEFIBRILLATOR (AICD) IN COMBINATION WITH AN ANTITACHYCARDIAL PACEMAKER [J].
GREVE, H ;
KOCH, T ;
GULKER, H ;
HEUER, H .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :2040-2044
[8]   THE MANAGEMENT OF PAROXYSMAL TACHYCARDIAS USING THE CYBERTACH-60 [J].
GRIFFIN, JC ;
SWEENEY, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1984, 7 (06) :1291-1295
[9]   AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (AICD) AND ANTITACHYCARDIA PACEMAKER (TACHYLOG) - COMBINED USE IN VENTRICULAR TACHYARRHYTHMIAS [J].
LUDERITZ, B ;
GERCKENS, U ;
MANZ, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1986, 9 (06) :1356-1360
[10]   PACEMAKER AND DEFIBRILLATOR COMBINATION THERAPY FOR RECURRENT VENTRICULAR-TACHYCARDIA [J].
MASTERSON, M ;
PINSKI, SL ;
WILKOFF, B ;
SIMMONS, TW ;
MORANT, VA ;
GOLDING, LR ;
CASTLE, LW ;
MALONEY, JD .
CLEVELAND CLINIC JOURNAL OF MEDICINE, 1990, 57 (04) :330-338