HIGH-PRECISION SAMPLING OF TRACE GAS-BORNE VOLATILES BY THE DYNAMIC SOLVENT EFFECT WITH A COMPARATIVE REVIEW OF ALTERNATIVE TECHNIQUES

被引:6
作者
APPS, PJ [1 ]
机构
[1] UNIV PRETORIA,INST CHROMATOG,PRETORIA 0002,SOUTH AFRICA
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 504卷 / 01期
关键词
D O I
10.1016/S0021-9673(01)89511-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The precise determination of traces of organic volatiles is particularly challenging in semiochemistry and clinical chemistry, where specimen sizes are intrinsically limited and amounts of trace components correspondingly very small. This demands a sampling technique that is fully compatible with the ability of capillary columns and gas chromatographic detectors to separate and quantify nanogram and sub-nanogram amounts from complex mixtures. The quantitative precision of dynamic solvent-effect sampling of low parts per billion (109) aqueous carbonyl compounds, high ppb and low parts per million aqueous phenols, low ppb and high parts per trillion (1012) airborne hydrocarbons and the volatiles from wine, human urine and a slow-release pesticide was tested with specimen sizes that yielded amounts of volatiles down to the sub-nanogram level. Provided that sources of variability, such as temperature changes, adsorption on containers, incomplete peak resolution and changes in the specimens themselves, were adequately controlled, dynamic solvent-effect sampling consistently provided coefficients of variation in peak areas, peak percentage areas and peak-area ratios of less than 10% at nanogram and sub-nanogram levels. The literature was surveyed for data on the performance of other sampling systems. None of them have been demonstrated to match the precision of the dynamic solvent effect with such small amounts from such a wide range of materials. © 1990.
引用
收藏
页码:21 / 43
页数:23
相关论文
共 67 条
[1]   DIRECT DETERMINATION OF TRACE AMOUNTS OF CHLOROPHENOLS IN FRESH-WATER, WASTEWATER AND SEA-WATER [J].
ABRAHAMSSON, K ;
XIE, TM .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :199-208
[2]   COMPARISON BETWEEN THE CONDITIONS FOR SOLUTE FOCUSING BY THE STATIC AND DYNAMIC SOLVENT EFFECTS UNDER IDEAL CONDITIONS [J].
APPS, PJ ;
PRETORIUS, V .
JOURNAL OF CHROMATOGRAPHY, 1989, 471 :81-89
[3]  
APPS PJ, 1988, ONDERSTEPOORT J VET, V55, P135
[4]   TRACE ANALYSIS OF COMPLEX ORGANIC MIXTURES USING CAPILLARY GAS-LIQUID-CHROMATOGRAPHY AND THE DYNAMIC SOLVENT EFFECT [J].
APPS, PJ ;
PRETORIUS, V ;
LAWSON, KH ;
ROHWER, ER ;
CENTNER, MR ;
VILJOEN, HW ;
HULSE, G .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (03) :122-127
[5]  
APPS PJ, 1988, AGGRESSIVE BEHAV, V14, P451, DOI 10.1002/1098-2337(1988)14:6<451::AID-AB2480140606>3.0.CO
[6]  
2-2
[7]  
APPS PJ, 1988, THESIS U PRETORIA PR, P98
[8]  
APPS PJ, 1988, THESIS U PRETORIA PR, P75
[9]  
APPS PJ, 1988, THESIS U PRETORIA PR, P147
[10]  
APPS PJ, UNPUB J CHROMATOGR