ASSESSMENT OF ANGIOGRAPHICALLY INTERMEDIATE CORONARY-ARTERY STENOSIS USING THE DOPPLER FLOWIRE

被引:61
作者
KERN, MJ
DONOHUE, TJ
AGUIRRE, FV
BACH, RG
CARACCIOLO, EA
OFILI, E
LABOVITZ, AJ
机构
[1] Cardiology Division, St. Louis University Hospital, St. Louis, MO
关键词
D O I
10.1016/0002-9149(93)90131-U
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Determination of the clinical and hemodynamic significance of coronary stenoses is often difficult and inexact. Angiography and coronary vasodilator reserve have been shown to be imperfect tools to determine the physiologic significance of coronary stenoses. Spectral flow velocity data, both proximal and distal to coronary stenoses, using an 0.018-in intracoronary Doppler-tipped angioplasty guidewire, were compared to translesional pressure gradients and angiography during cardiac catheterization. Patients were divided into 2 groups based on resting translesional gradients: Group 1 had gradients <20 mm Hg and group 2 had gradients greater-than-or-equal-to 20 mm Hg. Proximal average peak velocity, diastolic velocity integral, and total velocity integral were statistically significantly lower in Group 1. The distal average peak velocity, and diastolic and total velocity integrals were all significantly (p < 0.01) decreased in patients with gradients > 20 mm Hg (group 2). The ratio of proximal-to-distal total flow velocity integral was also higher in group 2 patients (2.3 +/- 0.9) compared with group 1 (1.1 +/- 0.2; p < 0.001). There was a strong correlation between translesional pressure gradients and the ratios of the proximal-to-distal total flow velocity integrals (r = 0.8, p < 0.001) with a weaker relationship between quantitative angiography and pressure gradients (r = 0.6, p < 0.001). Angiography was a poor predictor of translesional gradients in angiographically intermediate stenoses (range 50-70%; r = 0.2, p = NS), while the flow velocity ratios continued to have a strong correlation (r = 0.8, p <0.0001). Translesional coronary flow velocity is a new and easily applicable method for determining the hemodynamic significance of coronary stenoses that can be applied at the time of diagnostic catheterization. These data will provide a rational approach to decisions for questionable angiographic findings for coronary interventional techniques.
引用
收藏
页码:D26 / D33
页数:8
相关论文
共 24 条
  • [1] BLANKENHORN DH, 1982, ARCH PATHOL LAB MED, V106, P483
  • [2] NUCLEAR CARDIOLOGY .2. ROLE OF MYOCARDIAL PERFUSION IMAGING USING TL-201 IN DIAGNOSIS OF CORONARY HEART-DISEASE
    BODENHEIMER, MM
    BANKA, VS
    HELFANT, RH
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1980, 45 (03) : 674 - 684
  • [3] Caro CG, 1978, CARDIOVASCULAR PHYSL, P315
  • [4] DONOHUE T J, 1992, Journal of the American College of Cardiology, V19, p242A
  • [5] VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY
    DOUCETTE, JW
    CORL, PD
    PAYNE, HM
    FLYNN, AE
    GOTO, M
    NASSI, M
    SEGAL, J
    [J]. CIRCULATION, 1992, 85 (05) : 1899 - 1911
  • [6] PHYSIOLOGIC BASIS FOR ASSESSING CRITICAL CORONARY STENOSIS - INSTANTANEOUS FLOW RESPONSE AND REGIONAL DISTRIBUTION DURING CORONARY HYPEREMIA AS MEASURES OF CORONARY FLOW RESERVE
    GOULD, KL
    LIPSCOMB, K
    HAMILTON, GW
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1974, 33 (01) : 87 - 94
  • [7] PHYSIOLOGICAL SIGNIFICANCE OF CORONARY FLOW VELOCITY AND CHANGING STENOSIS GEOMETRY DURING CORONARY VASODILATION IN AWAKE DOGS
    GOULD, KL
    KELLEY, KO
    [J]. CIRCULATION RESEARCH, 1982, 50 (05) : 695 - 704
  • [8] GRODIN CM, 1974, CIRCULATION, V49, P703
  • [9] PREDICTION OF LONG-TERM CLINICAL OUTCOME WITH FINAL TRANSLESIONAL PRESSURE-GRADIENT DURING CORONARY ANGIOPLASTY
    HODGSON, JM
    REINERT, S
    MOST, AS
    WILLIAMS, DO
    [J]. CIRCULATION, 1986, 74 (03) : 563 - 566
  • [10] ASSESSMENT OF SEVERITY OF CORONARY STENOSES USING A DOPPLER CATHETER - VALIDATION OF A METHOD BASED ON THE CONTINUITY EQUATION
    JOHNSON, EL
    YOCK, PG
    HARGRAVE, VK
    SREBRO, JP
    MANUBENS, SM
    SEITZ, W
    PORTS, TA
    [J]. CIRCULATION, 1989, 80 (03) : 625 - 635