T1-WEIGHTED SEQUENCES FOR MR IMAGING OF THE LIVER - COMPARISON OF 3 TECHNIQUES FOR SINGLE-BREATH, WHOLE-VOLUME ACQUISITION AT 1.0-T AND 1.5-T

被引:58
作者
SEMELKA, RC
SIMM, FC
RECHT, M
DEIMLING, M
LENZ, G
LAUB, GA
机构
[1] ST BONIFACE GEN HOSP,RES CTR,WINNIPEG R2H 2A6,MANITOBA,CANADA
[2] SIEMENS AG,MED ENGN GRP,W-8520 ERLANGEN,GERMANY
关键词
LIVER; MR STUDIES; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; PULSE SEQUENCES; RAPID IMAGING;
D O I
10.1148/radiology.180.3.1871271
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The authors compared three T1-weighted magnetic resonance imaging techniques that acquire images encompassing the entire liver in one breath hold. Twenty healthy volunteers were imaged-10 at 1.0 T and 10 at 1.5 T-and the results compared with those of regular short repetition time/echo time spin-echo imaging. Rapid acquisition spin echo was resistant to artifacts and had good image quality but had the lowest liver signal-difference-to-noise (SD/N) values. Fast low-angle shot (FLASH) had the highest S/N and SD/N, very good image quality, and only mild artifacts. TurboFLASH had good S/N and SD/N, but reduced matrix size decreased image quality. All three sequences had better SD/N than regular spin echo, and FLASH and TurboFLASH had higher S/N. On the basis of this study, the FLASH sequence appears the most attractive for T1-weighted breath-hold imaging.
引用
收藏
页码:629 / 635
页数:7
相关论文
共 16 条
  • [1] BROOKEMAN JR, 1990, APPL RADIOL, V19, P12
  • [2] DATA EXTRAPOLATION FOR TRUNCATION ARTIFACT REMOVAL
    CONSTABLE, RT
    HENKELMAN, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (01) : 108 - 118
  • [3] DYNAMIC MR IMAGING OF THE LIVER WITH GD-DTPA - INITIAL CLINICAL-RESULTS
    EDELMAN, RR
    SIEGEL, JB
    SINGER, A
    DUPUIS, K
    LONGMAID, HE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) : 1213 - 1219
  • [4] SEGMENTED TURBOFLASH - METHOD FOR BREATH-HOLD MR IMAGING OF THE LIVER WITH FLEXIBLE CONTRAST
    EDELMAN, RR
    WALLNER, B
    SINGER, A
    ATKINSON, DJ
    SAINI, S
    [J]. RADIOLOGY, 1990, 177 (02) : 515 - 521
  • [5] CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T
    FOLEY, WD
    KNEELAND, JB
    CATES, JD
    KELLMAN, GM
    LAWSON, TL
    MIDDLETON, WD
    HENDRICK, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) : 1155 - 1160
  • [6] FLOW SUPPRESSION IN RAPID FLASH NMR IMAGES
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    HAASE, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1987, 4 (04) : 372 - 377
  • [7] DIFFERENTIATION OF HEPATIC HEMANGIOMAS FROM METASTASES BY DYNAMIC CONTRAST-ENHANCED MR IMAGING
    HAMM, B
    FISCHER, E
    TAUPITZ, M
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (02) : 205 - 216
  • [8] THE IMPORTANCE OF PHASE-ENCODING ORDER IN ULTRA-SHORT TR SNAPSHOT MR IMAGING
    HOLSINGER, AE
    RIEDERER, SJ
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (03) : 481 - 488
  • [9] RAPID ACQUISITION SPIN-ECHO (RASE) MR IMAGING - A NEW TECHNIQUE FOR REDUCTION OF ARTIFACTS AND ACQUISITION TIME
    MIROWITZ, SA
    LEE, JKT
    BROWN, JJ
    EILENBERG, SS
    HEIKEN, JP
    PERMAN, WH
    [J]. RADIOLOGY, 1990, 175 (01) : 131 - 135
  • [10] LIVER METASTASES - DETECTION WITH MR IMAGING AT 0.5 AND 1.5T
    REINIG, JW
    DWYER, AJ
    MILLER, DL
    FRANK, JA
    ADAMS, GW
    CHANG, AE
    [J]. RADIOLOGY, 1989, 170 (01) : 149 - 153