COGNITIVE FEEDBACK FOR USE WITH FES UPPER EXTREMITY NEUROPROSTHESES

被引:26
作者
RISO, RR
IGNAGNI, AR
KEITH, MW
机构
[1] CASE WESTERN RESERVE UNIV,DEPT ORTHOPED,CLEVELAND,OH 44106
[2] CASE WESTERN RESERVE UNIV,VET ADM,CTR REHABIL ENGN,CLEVELAND,OH 44106
[3] UNIV HOSP CLEVELAND,CLEVELAND,OH 44106
[4] METRO HLTH MED CTR,CLEVELAND,OH
[5] VET ADM MED CTR,CLEVELAND,OH 44106
关键词
D O I
10.1109/10.68206
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes the development of two sensory substitutions systems that provide cognitive feedback for FES hand grasp restoration neuroprostheses. One system uses an array of five electrodes to provide machine status information and a spatially encoded representation of the command signal that a quadriplegic individual generates to achieve proportional grasp control. Only one electrode site is active at any given instant, and a second informational channel is superimposed on the spatial position channel by modulating the frequency of the stimulus pulses. The frequency modulated feedback channel signals six levels of force developed at the finger tips during prehension activities. The second sensory system is an integral part of an implanted FES system and utilizes a single subdermally placed electrode to display machine status information and a five-level frequency code for feedback of the user generated grasp control signal. The multielectrode feedback system was implemented for laboratory studies using surface mounted electrodes, although its design will ultimately incorporate subdermal electrodes to provide a highly cosmetic and unencumbering system. An evaluation of the effectiveness of grasp force and command signal feedback provided by this multielectrode system in assisting an FES hand system user to regulate grasp force during a laboratory task, showed increased consistency of performance and an economy of grasp effort between 25 and 30%. Alternative strategies for feedback information and coding algorithms are discussed.
引用
收藏
页码:29 / 38
页数:10
相关论文
共 45 条
[1]   INFORMATION TRANSMISSION BY PHANTOM SENSATIONS [J].
ALLES, DS .
IEEE TRANSACTIONS ON MAN-MACHINE SYSTEMS, 1970, MM11 (01) :85-&
[2]  
[Anonymous], 1988, TACTILE SENSORS ROBO
[3]  
BUCKETT JR, 1985, 7TH P IEEE ANN C EMB, P314
[4]  
BUCKETT JR, 1980, P INT C REHAB ENG TO, P244
[5]   PERCUTANEOUS WIRE ELECTRODE FOR CHRONIC RESEARCH USE [J].
CALDWELL, CW ;
RESWICK, JB .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, 22 (05) :429-432
[6]  
CLIPPINGER RW, 1974, B PROS RES, V10, P247
[7]  
Collins C C, 1973, Adv Biol Med Phys, V14, P285
[8]   SENSORS FOR USE WITH FUNCTIONAL NEUROMUSCULAR STIMULATION [J].
CRAGO, PE ;
CHIZECK, HJ ;
NEUMAN, MR ;
HAMBRECHT, FT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :256-268
[9]   ADVENTURES IN TACTILE LITERACY [J].
GELDARD, FA .
AMERICAN PSYCHOLOGIST, 1957, 12 (02) :115-124
[10]   SOME NEGLECTED POSSIBILITIES OF COMMUNICATION [J].
GELDARD, FA .
SCIENCE, 1960, 131 (3413) :1583-1588