IRON(II) SULFATE (FRICKE SOLUTION) OXIDATION YIELDS FOR 8.9 AND 13.6 KEV X-RAYS FROM SYNCHROTRON RADIATION

被引:10
作者
HOSHI, M
UEHARA, S
YAMAMOTO, O
SAWADA, S
ASAO, T
KOBAYASHI, K
MAEZAWA, H
FURUSAWA, Y
HIEDA, K
YAMADA, T
机构
[1] LIFE ELECTR RES CTR,ELECTROTECH LAB,AMAGASAKI,HYOGO 661,JAPAN
[2] KYUSHU UNIV,SCH HLTH SCI,PHYS LAB,HIGASHI KU,FUKUOKA 812,JAPAN
[3] HIROSHIMA UNIV,FAC SCI,DEPT BIOL,NAKA KU,HIROSHIMA 730,JAPAN
[4] NATL LAB HIGH ENERGY PHYS,PHOTON LAB,TSUKUBA,IBARAKI 305,JAPAN
[5] TOKAI UNIV,SCH MED,ISEHARA,KANAGAWA 25911,JAPAN
[6] RIKKYO UNIV,FAC SCI,TOSHIMA KU,TOKYO 171,JAPAN
[7] NATL INST RADIOL SCI,CHIBA 260,JAPAN
关键词
D O I
10.1080/09553009214550581
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The oxidation yields (G) for 8.86 and 13.55 keV X-rays produced by synchrotron radiation were measured using an iron(II) sulphate (Fricke) solution. Monoenergetic X-rays were produced using a silicon crystal monochromator. The X-rays were absorbed in 0.4 M sulphuric acid-iron(II) sulphate solution and Fe(III) ion yields were measured and corrected for escape fractions resulting from scattering using Monte Carlo calculations. Doses in the solution were determined using a thin window, parallel plate chamber calibrated against a primary standard free-air chamber at the Electrotechnical Laboratory (Osaka, Japan). Yields (G) of 1.50 +/- 0.06 and 1.43 0.06-mu-mol J-1 were obtained for 8.86 and 13.55 keV X-rays respectively.
引用
收藏
页码:21 / 27
页数:7
相关论文
共 25 条
[1]  
ANTOKU S, 1960, ANN REP RES I NUCL M, V2, P1
[2]   REEVALUATION OF THE W-VALUE FOR ELECTRONS IN DRY AIR [J].
BOUTILLON, M ;
PERROCHEROUX, AM .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (02) :213-219
[3]   INACTIVATION OF SYNCHRONIZED MAMMALIAN-CELLS WITH LOW-ENERGY X-RAYS - RESULTS AND SIGNIFICANCE [J].
BRENNER, DJ ;
BIRD, RP ;
ZAIDER, M ;
GOLDHAGEN, P ;
KLIAUGA, PJ ;
ROSSI, HH .
RADIATION RESEARCH, 1987, 110 (03) :413-427
[4]  
Browne E., 1986, TABLE RADIOACTIVE IS
[5]   RADIOBIOLOGY OF ULTRASOFT X-RAYS .4. FLAT AND ROUND-SHAPED HAMSTER-CELLS (CHO-10B, HS-23) [J].
CARPENTER, S ;
CORNFORTH, MN ;
HARVEY, WF ;
RAJU, MR ;
SCHILLACI, ME ;
WILDER, ME ;
GOODHEAD, DT .
RADIATION RESEARCH, 1989, 119 (03) :523-533
[6]   MEASUREMENT OF THE G-VALUE FOR 1.5 KEV X-RAYS [J].
FREYER, JP ;
SCHILLACI, ME ;
RAJU, MR .
INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 1989, 56 (06) :885-892
[7]   AN ASSESSMENT OF THE ROLE OF MICRODOSIMETRY IN RADIOBIOLOGY [J].
GOODHEAD, DT .
RADIATION RESEARCH, 1982, 91 (01) :45-76
[8]  
GOODHEAD DT, 1984, RAD CARCINOGENESIS E, P369
[9]   SATURATION CHARACTERISTICS OF PARALLEL-PLATE IONIZATION CHAMBERS [J].
GREENING, JR .
PHYSICS IN MEDICINE AND BIOLOGY, 1964, 9 (02) :143-&
[10]   DOSIMETRY COMPARISON AND CHARACTERIZATION OF AN AL K ULTRASOFT X-RAY-BEAM FROM AN MRC COLD-CATHODE SOURCE [J].
HOSHI, M ;
GOODHEAD, DT ;
BRENNER, DJ ;
BANCE, DA ;
CHMIELEWSKI, JJ ;
PACIOTTI, MA ;
BRADBURY, JN .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (10) :1029-1041