The work describes the development of a novel sequence that uses rapid spiral k-space sampling, combined with phase velocity mapping, for real time flow velocity imaging. The performance of the technique is assessed on phantoms for both through-plane and in-plane flows. The flow measurements compared well with those measured using a bucket and stopwatch. One advantage of the technique is that flow related signal loss is minimal due to the early acquisition of the center of k-space data. Flow artifacts were observed for in-plane flow and these were understood with the aid of computer simulations. In vivo studies involved cine velocity mapping in normal volunteers; aortic blood flow waveforms acquired by spiral scanning in two cardiac cycles compared well with data from a conventional gradient-echo sequence. Potential applications of the method are demonstrated by studying the response of aortic flow to physical exercise and the real time monitoring of aortic flow during a valsalver maneuver.
引用
收藏
页码:504 / 512
页数:9
相关论文
共 23 条
[1]   HIGH-SPEED SPIRAL-SCAN ECHO PLANAR NMR IMAGING .1. [J].
AHN, CB ;
KIM, JH ;
CHO, ZH .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1986, 5 (01) :2-7
[2]   MEASUREMENT OF FLOW WITH NMR IMAGING USING A GRADIENT PULSE AND PHASE DIFFERENCE TECHNIQUE [J].
BRYANT, DJ ;
PAYNE, JA ;
FIRMIN, DN ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1984, 8 (04) :588-593
[3]  
BUTTS RK, 1993, MAG RESON MED, V29, P143
[4]  
BUTTS RK, 1992, J MAGN RESON IMAGING, V2, P285
[5]   THEORETICAL ASPECTS OF MOTION SENSITIVITY AND COMPENSATION IN ECHO-PLANAR IMAGING [J].
DUERK, JL ;
SIMONETTI, OP .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1991, 1 (06) :643-650
[6]   INVIVO VALIDATION OF MR VELOCITY IMAGING [J].
FIRMIN, DN ;
NAYLER, GL ;
KLIPSTEIN, RH ;
UNDERWOOD, SR ;
REES, RSO ;
LONGMORE, DB .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (05) :751-756
[7]   ECHO-PLANAR HIGH-RESOLUTION FLOW VELOCITY MAPPING [J].
FIRMIN, DN ;
KLIPSTEIN, RH ;
HOUNSFIELD, GL ;
PALEY, MP ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1989, 12 (03) :316-327
[8]  
FIRMIN DN, 1990, 9TH P SMRM ANN M, P408
[9]  
HAASE A, 1986, J MAGN RESON, V67, P217
[10]   BROAD-BAND NUCLEAR MAGNETIC-RESONANCE PULSES WITH TWO-DIMENSIONAL SPATIAL SELECTIVITY [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (04) :1513-1516