TEMPERATURE DISTRIBUTIONS INSIDE ELECTRICAL HOT-WATER STORAGE TANKS

被引:4
作者
ALNIMR, MA
机构
[1] Mechanical Engineering Department, Jordan University of Science and Technology, Irbid
关键词
Flow of water - Mathematical models - Parameter estimation - Temperature distribution - Thermal stratification;
D O I
10.1016/0306-2619(94)90005-1
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The presented mathematical model is solved analytically to determine: (i) the effect of different design parameters on the thermal stratification within the tank; (ii) the time required by the tank to supply water with a specified outlet temperature.
引用
收藏
页码:353 / 362
页数:10
相关论文
共 10 条
[1]  
ALNIMR MA, IN PRESS J SOLAR ENE
[2]  
DUFFIE JA, 1991, SOLAR ENG THERMAL PR, pCH8
[3]   A CONTROLLED BUOYANT JET FOR ENHANCING STRATIFICATION IN A LIQUID STORAGE TANK [J].
GARI, HN ;
LOEHRKE, RI .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (04) :475-481
[4]  
Issa M., 1989, Transactions of the ASME. Journal of Solar Energy Engineering, V111, P311, DOI 10.1115/1.3268328
[5]   EXPERIMENTAL-STUDY OF THERMALLY STRATIFIED HOT WATER STORAGE TANKS [J].
LAVAN, Z ;
THOMPSON, J .
SOLAR ENERGY, 1977, 19 (05) :519-524
[6]  
MIKHLIN SG, 1967, LINEAR EQUATIONS MAT
[7]  
OZISIK MN, 1980, HEAT CONDUCTION, pCH6
[8]   DYNAMIC SIMULATION OF A DOMESTIC HOT-WATER SYSTEM [J].
PARKER, GJ ;
TUCKER, AS .
APPLIED ENERGY, 1991, 40 (01) :1-19
[9]   OFF-PEAK ENERGY-STORAGE FOR DOMESTIC APPLICATIONS IN CHRISTCHURCH, NEW-ZEALAND [J].
PARKER, GJ .
APPLIED ENERGY, 1993, 44 (03) :259-281
[10]  
SNEK WJ, AICHE S SERIES, V70, P130