INFLUENCE OF CALIBRATION MATERIALS IN SINGLE-ENERGY AND DUAL-ENERGY QUANTITATIVE CT

被引:14
作者
STEENBEEK, JCM
VANKUIJK, C
GRASHUIS, JL
机构
[1] ERASMUS UNIV,DEPT RADIOL,3000 DR ROTTERDAM,NETHERLANDS
[2] ERASMUS UNIV,DEPT MED INFORMAT,3000 DR ROTTERDAM,NETHERLANDS
[3] ACAD HOSP ROTTERDAM,ROTTERDAM,NETHERLANDS
关键词
COMPUTED TOMOGRAPHY (CT); DUAL-ENERGY; SPINE; ANATOMY;
D O I
10.1148/radiology.183.3.1584946
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
With single-energy (SE) quantitative computed tomography (CT), the density of bone mineral in the vertebral body can be estimated. With dual-energy (DE) quantitative CT, both bone-mineral density and fat content can be measured. The calibration device normally used contains materials mimicking trabecular bone, fat, and hematopoietic tissue. To evaluate the influence of different calibration materials on these estimates, theoretical CT numbers were calculated for the trabecular part of the vertebral body and for different calibration devices. Calibration devices were simulated; they contained either identical materials or various accepted tissue-mimicking materials. For all combinations, quantitative CT data were generated for the SE quantitative CT method and for two DE quantitative CT methods. Only one method provided accurate results under ideal circumstances. The selection of tissue-mimicking materials in the calibration devices is important for the interpretation of results of SE and DE quantitative CT. Errors of more than a factor 2 were found when different types of materials were used.
引用
收藏
页码:849 / 855
页数:7
相关论文
共 38 条
[1]  
ARNOLD J. S., 1966, CLIN ORTHOP RELATED RES, V49, P17
[2]   CHANGES IN TRABECULAR BONE, HEMATOPOIESIS AND BONE-MARROW VESSELS IN APLASTIC-ANEMIA, PRIMARY OSTEOPOROSIS, AND OLD-AGE - A COMPARATIVE HISTOMORPHOMETRIC STUDY [J].
BURKHARDT, R ;
KETTNER, G ;
BOHM, W ;
SCHMIDMEIER, M ;
SCHLAG, R ;
FRISCH, B ;
MALLMANN, B ;
EISENMENGER, W ;
GILG, T .
BONE, 1987, 8 (03) :157-164
[3]   PRECISE MEASUREMENT OF VERTEBRAL MINERAL-CONTENT USING COMPUTED-TOMOGRAPHY [J].
CANN, CE ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1980, 4 (04) :493-500
[4]   QUANTITATIVE CT FOR DETERMINATION OF BONE-MINERAL DENSITY - A REVIEW [J].
CANN, CE .
RADIOLOGY, 1988, 166 (02) :509-522
[5]   QUANTIFICATION OF CALCIUM IN SOLITARY PULMONARY NODULES USING SINGLE-ENERGY AND DUAL-ENERGY CT [J].
CANN, CE ;
GAMSU, G ;
BIRNBERG, FA ;
WEBB, WR .
RADIOLOGY, 1982, 145 (02) :493-496
[6]   A THEORETICAL-ANALYSIS OF THE ACCURACY OF SINGLE-ENERGY CT BONE-MINERAL MEASUREMENTS [J].
CRAWLEY, EO ;
EVANS, WD ;
OWEN, GM .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (10) :1113-1127
[7]   QUANTITATIVE HISTOLOGICAL STUDIES ON AGE CHANGES IN BONE [J].
DUNNILL, MS ;
ANDERSON, JA ;
WHITEHEAD, R .
JOURNAL OF PATHOLOGY AND BACTERIOLOGY, 1967, 94 (02) :275-+
[8]   PHYSICAL PROPERTIES OF TRABECULAR BONE [J].
GALANTE, J ;
ROSTOKER, W ;
RAY, RD .
CALCIFIED TISSUE RESEARCH, 1970, 5 (03) :236-&
[9]   QUANTITATIVE BONE-MINERAL ANALYSIS USING DUAL ENERGY COMPUTED TOMOGRAPHY [J].
GENANT, HK ;
BOYD, D .
INVESTIGATIVE RADIOLOGY, 1977, 12 (06) :545-551
[10]   VERTEBRAL MINERAL DETERMINATION BY QUANTITATIVE COMPUTED-TOMOGRAPHY (QCT) - ACCURACY OF SINGLE AND DUAL ENERGY MEASUREMENTS [J].
GLUER, CC ;
REISER, UJ ;
DAVIS, CA ;
RUTT, BK ;
GENANT, HK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1988, 12 (02) :242-258