APPLICATION OF A BEDSIDE WHOLE-BLOOD D-DIMER ASSAY IN THE DIAGNOSIS OF DEEP-VEIN THROMBOSIS

被引:55
作者
BRENNER, B
PERY, M
LANIR, N
JABAREEN, A
MARKEL, A
KAFTORI, JK
GAITINI, D
RYLATT, D
机构
[1] RAMBAM MED CTR,ULTRASOUND UNIT,IL-31096 HAIFA,ISRAEL
[2] RAMBAM MED CTR,DEPT INTERNAL MED,IL-31096 HAIFA,ISRAEL
[3] TECHNION ISRAEL INST TECHNOL,FAC MED,HAIFA,ISRAEL
[4] AGEN BIOMED,ACACIA RIDGE,AUSTRALIA
关键词
FIBRINOLYSIS; VENOUS THROMBOSIS; FIBRIN DEGRADATION PRODUCTS;
D O I
10.1097/00001721-199505000-00004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cross-linked fibrin degradation products have been used to detect venous thrombosis. While the sensitivity of plasma D-dimer measured by ELISA in the diagnosis of deep vein thrombosis (DVT) is high, the utility of ELISA methods is limited in a clinical setting. This study analysed the diagnostic value of a rapid D-dimer assay performed on whole blood samples (SimpliRed D-dimer) compared with latex and ELISA in 86 patients suspected of having DVT. SimpliRed D-dimer was positive in 47/50 of patients with DVT established by Doppler ultrasound (DU; sensitivity 94%). SimpliRed D-dimer was positive in 35/37 of patients with proximal DVT, nine out of nine with popliteal DVT and three out of four with superficial thrombophlebitis. The specificity of SimpliRed D-dimer in the diagnosis of DVT was 61%. The sensitivity of the SimpliRed D-dimer assay was at least comparable with the ELISA (87%) and superior to the latex assay (80%). The positive predictive value (77%), the negative predictive value (88%) and the overall accuracy (80%) of the SimpliRed assay were better than the ELISA and latex methods. It is concluded that SimpliRed D-dimer is a rapid useful assay for screening of patients suspected of having deep vein thrombosis.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 22 条
[1]   LIMITATIONS OF IMPEDANCE PLETHYSMOGRAPHY IN THE DIAGNOSIS OF CLINICALLY SUSPECTED DEEP-VEIN THROMBOSIS [J].
ANDERSON, DR ;
LENSING, AWA ;
WELLS, PS ;
LEVINE, MN ;
WEITZ, JI ;
HIRSH, J .
ANNALS OF INTERNAL MEDICINE, 1993, 118 (01) :25-30
[2]  
BONEU B, 1991, THROMB HAEMOSTASIS, V65, P28
[3]   MEASUREMENT OF PLASMA D-DIMER FOR DIAGNOSIS OF DEEP VENOUS THROMBOSIS [J].
BOUNAMEAUX, H ;
SCHNEIDER, PA ;
REBER, G ;
DEMOERLOOSE, P ;
KRAHENBUHL, B .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1989, 91 (01) :82-85
[4]  
BOUNAMEAUX H, 1994, THROMB HAEMOSTASIS, V7, P1
[5]   QUANTITATION OF VENOUS CLOT LYSIS WITH THE D-DIMER IMMUNOASSAY DURING FIBRINOLYTIC THERAPY REQUIRES CORRECTION FOR SOLUBLE FIBRIN DEGRADATION [J].
BRENNER, B ;
FRANCIS, CW ;
TOTTERMAN, S ;
KESSLER, CM ;
RAO, AK ;
RUBIN, R ;
KWAAN, HC ;
GABRIEL, KR ;
MARDER, VJ .
CIRCULATION, 1990, 81 (06) :1818-1825
[6]  
BRENNER B, 1989, J LAB CLIN MED, V113, P682
[7]  
CARTER CJ, 1993, THROMB HAEMOSTASIS, V69, P8
[8]  
CHANGLIEM GS, 1991, HAEMOSTASIS, V21, P106
[9]  
CHAPMAN CS, 1990, CLIN LAB HAEMATOL, V12, P37
[10]  
DALE S, 1994, THROMB HAEMOSTASIS, V71, P270