COMPARISON OF 2 FIBEROPTIC L-GLUTAMATE BIOSENSORS BASED ON THE DETECTION OF OXYGEN OR CARBON-DIOXIDE, AND THEIR APPLICATION IN COMBINATION WITH FLOW-INJECTION ANALYSIS TO THE DETERMINATION OF GLUTAMATE

被引:42
作者
DREMEL, BAA [1 ]
SCHMID, RD [1 ]
WOLFBEIS, OS [1 ]
机构
[1] GRAZ UNIV,INST ORGAN CHEM,DIV ANALYT,A-8010 GRAZ,AUSTRIA
关键词
FLOW SYSTEM; FLUOROMETRY; BIOSENSORS; FIBEROPTIC SENSOR; FOODS; GLUTAMATE; PHARMACEUTICALS;
D O I
10.1016/S0003-2670(00)84651-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system for the fibre-optical determination of L-glutamate in food and pharmaceutical preparations that makes use of two kinds of fibre-optic biosensors is presented. In the first type, an oxygen-sensitive optrode was covered with a membrane onto which was immobilized L-glutamate oxidase. The decrease in oxygen partial pressure in the presence of glutamate as a result of enzymatic reaction was determined via dynamic quenching of the fluorescence of an oxygen-sensitive indicator dye. In the second type, a carbon dioxide-sensitive optrode was covered with a membrane of immobilized L-glutamate decarboxylase. The production of carbon dioxide in the presence of substrate was determined via the changes in the pH of a carbon dioxide sensor consisting of a membrane-covered pH-sensitive fluorescent pH indicator dye entrapped in a hydrogencarbonate buffer. The oxygen optrode-based glutamate biosensor shows a linear response from 0.02 to 1.0 mM glutamate with an relative standard deviation (r.s.d.) of 3% at the 2 mM level (5 measurements). The carbon dioxide optrode-based glutamate biosensor shows a linear response from 0.1 to 2.5 mM glutamate, with an r.s.d. of 3% at the 2.5 mM level (5 measurements). The application of both biosensor optrodes to determinations of L-glutamate in food and pharmaceutical samples is demonstrated. The advantages and disadvantages of both the oxygen and carbon dioxide optrodes are discussed in terms of sensitivity, selectivity and response time.
引用
收藏
页码:351 / 359
页数:9
相关论文
共 37 条
[1]  
Bates RG, 1973, DETERMINATION PH THE, P8
[2]  
BELITZ HD, 1985, LEHRBUCH LEBENSMITTE, P338
[3]   A NOVEL L-GLUTAMATE OXIDASE FROM STREPTOMYCES-ENDUS - PURIFICATION AND PROPERTIES [J].
BOHMER, A ;
MULLER, A ;
PASSARGE, M ;
LIEBS, P ;
HONECK, H ;
MULLER, HG .
EUROPEAN JOURNAL OF BIOCHEMISTRY, 1989, 182 (02) :327-332
[4]  
COOPER PP, 1986, FOOD COSMET TOXICOL, V15, P347
[5]   SELECTIVITY ENHANCEMENT OF AN ESCHERICHIA-COLI BACTERIAL ELECTRODE USING ENZYME AND TRANSPORT INHIBITORS [J].
CORCORAN, CA ;
KOBOS, RK .
BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (04) :565-570
[6]   FEASIBILITY OF CONTINUOUS GLUTAMATE MONITORING IN PERFUSED RETINAL TISSUE WITH A POTENTIOMETRIC BIOSENSING PROBE [J].
DIAZ, GV ;
ELISSA, LH ;
ARNOLD, MA ;
MILLER, RF .
JOURNAL OF NEUROSCIENCE METHODS, 1988, 23 (01) :63-69
[7]  
ENGELSEN B, 1986, ACTA NEUROL SCAND, V74, P337
[8]   IMPROVEMENT IN THE RESOLUTION OF ORTHO-PHTHALALDEHYDE DERIVATIZED AMINO-ACIDS BY APPLYING GRADIENT STEEPNESS OPTIMIZATION TO 5 REVERSED-PHASE COLUMNS OF DIFFERENT LENGTHS AND PARTICLE SIZES [J].
ESLAMI, M ;
STUART, JD ;
COHEN, KA .
JOURNAL OF CHROMATOGRAPHY, 1987, 411 :121-138
[9]   INHIBITION OF BACTERIAL GLUTAMATE-DECARBOXYLASE BY TRICARBOXYLIC-ACID CYCLE INTERMEDIATES [J].
GERIG, JT ;
KWOCK, L .
FEBS LETTERS, 1979, 105 (01) :155-157
[10]   SEPARATION OF AMINO-ACIDS ON REVERSED-PHASE COLUMNS AS THEIR COPPER(II) COMPLEXES [J].
GRUSHKA, E ;
LEVIN, S ;
GILON, C .
JOURNAL OF CHROMATOGRAPHY, 1982, 235 (02) :401-409