KINETIC-STUDY OF THE PERFORMANCE OF 3RD-GENERATION BIOSENSORS

被引:29
作者
KOOPAL, CGJ [1 ]
NOLTE, RJM [1 ]
机构
[1] UNIV NIJMEGEN,NIJMEGEN SON RES CTR,6525 ED NIJMEGEN,NETHERLANDS
来源
BIOELECTROCHEMISTRY AND BIOENERGETICS | 1994年 / 33卷 / 01期
关键词
D O I
10.1016/0302-4598(94)87031-4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
A kinetic study of the performance of third-generation biosensors for glucose based on glucose oxidase immobilized on a microporous matrix of the conducting polymer poly(pyrrole) is presented. The mechanism of the enzymatically catalyzed oxidation of glucose will be different in this type of biosensor as the natural electron acceptor oxygen is replaced by the conducting polymer. Different kinetic parameters are found for the immobilized glucose oxidase than for the enzyme in solution. Mediation by the conducting polymer is found to be very effective and no significant electron transfer to oxygen is observed. In addition to substrate transport limitation in the microporous matrix, the enzymatic reaction in the biosensors is limited by the applied potential.
引用
收藏
页码:45 / 53
页数:9
相关论文
共 53 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .2. CONDUCTING SALTS AS ELECTRODE MATERIALS FOR THE OXIDATION OF GLUCOSE-OXIDASE [J].
ALBERY, WJ ;
BARTLETT, PN ;
CRASTON, DH .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :223-235
[2]   AMPEROMETRIC ENZYME ELECTRODES .1. THEORY [J].
ALBERY, WJ ;
BARTLETT, PN .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1985, 194 (02) :211-222
[3]   DEUTERIUM AND TRITIUM EXCHANGE IN ENZYME-KINETICS [J].
ALBERY, WJ ;
KNOWLES, JR .
BIOCHEMISTRY, 1976, 15 (25) :5588-5600
[4]   DETERMINATION OF GLUCOSE USING FLOW-INJECTION WITH A CARBON-FIBER BASED ENZYME REACTOR [J].
ANG, KP ;
GUNASINGHAM, H ;
TAY, BT ;
HERATH, VS ;
TEO, PYT ;
THIAK, PC ;
KUAH, B ;
TAN, KL .
ANALYST, 1987, 112 (10) :1433-1435
[5]   THE ELECTRODEPOSITION OF POLYPYRROLE FILMS FROM AQUEOUS-SOLUTIONS [J].
ASAVAPIRIYANONT, S ;
CHANDLER, GK ;
GUNAWARDENA, GA ;
PLETCHER, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1984, 177 (1-2) :229-244
[6]  
Bard A. J., 2001, ELECTROCHEMICAL METH, V2nd, P50
[7]   ELECTROCHEMICAL IMMOBILIZATION OF ENZYMES .2. GLUCOSE-OXIDASE IMMOBILIZED IN POLY-N-METHYLPYRROLE [J].
BARTLETT, PN ;
WHITAKER, RG .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 224 (1-2) :37-48
[8]   ELECTROCHEMICAL STUDY OF D-GLUCOSE OXIDASE AUTO-INACTIVATION [J].
BOURDILLON, C ;
THOMAS, V ;
THOMAS, D .
ENZYME AND MICROBIAL TECHNOLOGY, 1982, 4 (03) :175-180
[9]  
Cass A.E.G., 1990, BIOSENSORS PRACTICAL
[10]   FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE [J].
CASS, AEG ;
DAVIS, G ;
FRANCIS, GD ;
HILL, HAO ;
ASTON, WJ ;
HIGGINS, IJ ;
PLOTKIN, EV ;
SCOTT, LDL ;
TURNER, APF .
ANALYTICAL CHEMISTRY, 1984, 56 (04) :667-671