WET, A T-1-INSENSITIVE AND B-1-INSENSITIVE WATER-SUPPRESSION METHOD FOR IN-VIVO LOCALIZED H-1-NMR SPECTROSCOPY

被引:603
作者
OGG, RJ
KINGSLEY, PB
TAYLOR, JS
机构
[1] Department of Diagnostic Imaging, St. Jude Children’s Research Hospital, Memphis, TN 38101
来源
JOURNAL OF MAGNETIC RESONANCE SERIES B | 1994年 / 104卷 / 01期
关键词
D O I
10.1006/jmrb.1994.1048
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
Suppression of the water signal during H-1 magnetic resonance spectroscopy by repeated sequences of a frequency-selective radiofrequency pulse and a gradient dephasing pulse requires nulling of the longitudinal component of the water magnetization and is therefore affected by T-1 relaxation, RE-pulse flip angles (which depend on B-1), and sequence timing. In in vivo applications, T-1 and B-1 inhomogeneity within the sample may cause spatially inhomogeneous water suppression. An improved water-suppression technique called WET (water suppression enhanced through T-1 effects), developed from a Bloch equation analysis of the longitudinal magnetization over the T-1 and B-1 ranges of interest, achieves T-1- and B-1-insensitive suppression with four RF pulses, each having a numerically optimized flip angle. Once flip angles have been optimized for a given sequence, time-consuming flip-angle adjustments during clinical examinations are eliminated. This water-suppression technique was characterized with respect to T-1 variations, B-1 variations, off-resonance effects, and partial saturation effects and was compared to similar techniques. Effective water suppression has been achieved with this new technique in single-voxel spectroscopy examinations of more than 50 brain tumor patients at 1.5 T. (C) 1994 Academic Press, Inc.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 22 条
[1]   SUPPRESSION OF ARTIFACTS IN MULTIPLE-ECHO MAGNETIC-RESONANCE [J].
BARKER, GJ ;
MARECI, TH .
JOURNAL OF MAGNETIC RESONANCE, 1989, 83 (01) :11-28
[2]   A REVIEW OF H-1 NUCLEAR-MAGNETIC-RESONANCE RELAXATION IN PATHOLOGY - ARE T1 AND T2 DIAGNOSTIC [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ARGERSINGER, RE ;
ALLENMOORE, G .
MEDICAL PHYSICS, 1987, 14 (01) :1-37
[3]   SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO [J].
BOTTOMLEY, PA .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 :333-348
[4]   THE DYNAMIC-RANGE PROBLEM IN NMR [J].
DAVIES, S ;
BAUER, C ;
BARKER, P ;
FREEMAN, R .
JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) :155-159
[5]   WATER SIGNAL ELIMINATION INVIVO, USING SUPPRESSION BY MISTIMED ECHO AND REPETITIVE GRADIENT EPISODES [J].
DODDRELL, DM ;
GALLOWAY, GJ ;
BROOKS, WM ;
FIELD, J ;
BULSING, JM ;
IRVING, MG ;
BADDELEY, H .
JOURNAL OF MAGNETIC RESONANCE, 1986, 70 (01) :176-180
[6]   3D PHASE ENCODING H-1 SPECTROSCOPIC IMAGING OF HUMAN BRAIN [J].
DUIJN, JH ;
MATSON, GB ;
MAUDSLEY, AA ;
WEINER, MW .
MAGNETIC RESONANCE IMAGING, 1992, 10 (02) :315-319
[7]  
ERNST RR, 1987, PRINCIPLES NUCLEAR M, P123
[8]   IMPROVEMENTS IN LOCALIZED PROTON NMR-SPECTROSCOPY OF HUMAN BRAIN - WATER SUPPRESSION, SHORT ECHO TIMES, AND 1-ML RESOLUTION [J].
FRAHM, J ;
MICHAELIS, T ;
MERBOLDT, KD ;
BRUHN, H ;
GYNGELL, ML ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1990, 90 (03) :464-473
[9]   LOCALIZED PROTON SPECTROSCOPY USING STIMULATED ECHOES [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W .
JOURNAL OF MAGNETIC RESONANCE, 1987, 72 (03) :502-508
[10]   ADAPTIVE SCHEME FOR MEASURING NMR SPIN-LATTICE RELAXATION-TIMES [J].
FREEMAN, R ;
KAPTEIN, R ;
HILL, HDW .
JOURNAL OF MAGNETIC RESONANCE, 1972, 7 (01) :82-&