COMPARISON OF DIAGNOSTIC-TECHNIQUES FOR THE DETECTION OF A PATENT FORAMEN OVALE IN STROKE PATIENTS

被引:238
作者
DITULLIO, M
SACCO, RL
VENKETASUBRAMANIAN, N
SHERMAN, D
MOHR, JP
HOMMA, S
机构
[1] COLUMBIA UNIV,DEPT MED,NEW YORK,NY 10027
[2] COLUMBIA UNIV,DEPT NEUROL,NEW YORK,NY 10027
关键词
CEREBROVASCULAR DISORDERS; DOPPLER; ECHOCARDIOGRAPHY; FORAMEN OVALE; PATENT;
D O I
10.1161/01.STR.24.7.1020
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose: The prevalence of a patent foramen ovale has been shown to be increased in patients with ischemic stroke. Transesophageal echocardiography, transthoracic echocardiography, and transcranial Doppler examination with contrast injection can all be used to search for a patent foramen ovale. We compared the accuracy of these techniques for identifying a patent foramen ovale in 49 patients with acute ischemic stroke or transient ischemic attack. Methods: Transcranial Doppler examination of the right middle cerebral artery was performed during simultaneous transthoracic echocardiography with aerated saline injection, and again during transesophageal echocardiography; the latter was adopted as the ''gold standard'' for assessing the sensitivity of the other two tests. Results: Contrast transesophageal echocardiography detected a patent foramen ovale in 19 of 49 patients (39%), during normal respiration in 15 of them and during Valsalva maneuver in 4. Transcranial Doppler correctly identified 13 patients with a patent foramen ovale and all 30 patients without it. Therefore, the sensitivity of transcranial Doppler was 68% (13/19), and its specificity 100% (30/30). The 6 patients misclassified by transcranial Doppler (false negatives) had a very small right-to-left shunt detected by transesophageal echocardiography. Contrast transthoracic echocardiography was found to be the least sensitive test, detecting a patent foramen ovale in only 9 of 19 patients (47%). The specificity of transthoracic echocardiography was 100% (30/30 patients). The low sensitivity of transthoracic echocardiography was principally due to the suboptimal image quality obtained in false-negative patients. Both transcranial Doppler and transthoracic echocardiography were more sensitive in patients with cryptogenic stroke than in patients with stroke of determined origin. This may indicate the presence of larger, more easily detectable shunts in patients with cryptogenic stroke. Conclusions: Transesophageal echocardiography is more sensitive than transcranial Doppler examination in detecting a patent foramen ovale, but only in cases of minimal right-to-left shunts, the clinical relevance of which remains to be established. The sensitivity of transthoracic echocardiography is heavily hampered by the frequency of inadequate heart visualization.
引用
收藏
页码:1020 / 1024
页数:5
相关论文
共 24 条
  • [1] FURTHER OBSERVATIONS ON CEREBRAL OR RETINAL ISCHEMIA IN PATIENTS WITH RIGHT-LEFT INTRACARDIAC SHUNTS
    BILLER, J
    JOHNSON, MR
    ADAMS, HP
    KERBER, RE
    CORBETT, JJ
    BRUNO, A
    LETH, RJ
    [J]. ARCHIVES OF NEUROLOGY, 1987, 44 (07) : 740 - 743
  • [2] ATRIAL SEPTAL-DEFECT - LESSONS FROM THE PAST, DIRECTIONS FOR THE FUTURE
    BOROW, KM
    KARP, R
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1990, 323 (24) : 1698 - 1700
  • [3] TRANSESOPHAGEAL ECHOCARDIOGRAPHY IN THE DETECTION OF POTENTIAL CARDIAC SOURCE OF EMBOLISM IN STROKE PATIENTS
    CUJEC, B
    POLASEK, P
    VOLL, C
    SHUAIB, A
    [J]. STROKE, 1991, 22 (06) : 727 - 733
  • [4] PATENT FORAMEN OVALE AS A RISK FACTOR FOR CRYPTOGENIC STROKE
    DITULLIO, M
    SACCO, RL
    GOPAL, A
    MOHR, JP
    HOMMA, S
    [J]. ANNALS OF INTERNAL MEDICINE, 1992, 117 (06) : 461 - 465
  • [5] DITULLIO M, 1991, CIRCULATION, V84, P451
  • [6] CONTRAST ECHOCARDIOGRAPHIC VISUALIZATION OF COUGH-INDUCED RIGHT TO LEFT SHUNT THROUGH A PATENT FORAMEN OVALE
    DUBOURG, O
    BOURDARIAS, JP
    FARCOT, JC
    GUERET, P
    TERDJMAN, M
    FERRIER, A
    RIGAUD, M
    BARDET, JC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1984, 4 (03) : 587 - 594
  • [7] CLINICALLY SILENT ATRIAL SEPTAL-DEFECTS WITH EVIDENCE FOR CEREBRAL EMBOLIZATION
    HARVEY, JR
    TEAGUE, SM
    ANDERSON, JL
    VOYLES, WF
    THADANI, U
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 105 (05) : 695 - 697
  • [8] DIAGNOSIS OF PATENT FORAMEN OVALE BY TRANSESOPHAGEAL ECHOCARDIOGRAPHY AND ASSOCIATION WITH CEREBRAL AND PERIPHERAL EMBOLIC EVENTS
    HAUSMANN, D
    MUGGE, A
    BECHT, I
    DANIEL, WG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (06) : 668 - 672
  • [9] HOFFMANN T, 1990, LANCET, V336, P1421
  • [10] CEREBRAL EMBOLI OF PARADOXICAL ORIGIN
    JONES, HR
    CAPLAN, LR
    COME, PC
    SWINTON, NW
    BRESLIN, DJ
    [J]. ANNALS OF NEUROLOGY, 1983, 13 (03) : 314 - 319