ADDITION OF NOISE BY SCATTER CORRECTION METHODS IN PVI

被引:3
作者
BARNEY, JS [1 ]
HARROP, R [1 ]
ATKINS, MS [1 ]
机构
[1] SIMON FRASER UNIV,SCH COMP SCI,BURNABY V5A 1S6,BC,CANADA
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1109/23.322947
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Effective scatter correction techniques are required to account for errors due the high scatter fraction seen in positron volume imaging (PVI). To be effective, the correction techniques must be accurate and practical, but they also must not add excessively to the statistical noise in the image. We have investigated the noise added by three correction methods: a convolution/subtraction method; a method that interpolates the scatter from the events outside the object; and a dual energy window method with and without smoothing of the scatter estimate. The methods were applied to data generated by Monte Carlo simulation to determine their effect on the variance of the corrected projections. The convolution and interpolation methods did not add significantly to the variance. The dual energy window subtraction method without smoothing increased the variance by a factor of more than twelve, but this factor was improved to 1.2 by smoothing the scatter estimate.
引用
收藏
页码:1551 / 1555
页数:5
相关论文
共 11 条
[1]   NOISE EQUIVALENT COUNT MEASUREMENTS IN A NEURO-PET SCANNER WITH RETRACTABLE SEPTA [J].
BAILEY, DL ;
JONES, T ;
SPINKS, TJ ;
GILARDI, MC ;
TOWNSEND, DW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :256-260
[2]  
BARNEY J, 1993, THESIS S FRASER U
[3]   OBJECT SHAPE DEPENDENT SCATTER SIMULATIONS FOR PET [J].
BARNEY, JS ;
ROGERS, JG ;
HARROP, R ;
HOVERATH, H .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1991, 38 (02) :719-725
[4]   SOURCE DISTRIBUTION DEPENDENT SCATTER CORRECTION FOR PVI [J].
BARNEY, JS ;
HARROP, R ;
DYKSTRA, CJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1001-1007
[5]  
GROOTOONK S, 1991, 1991 IEEE NUCL SCI S, P1569
[6]  
GROOTOONK S, 1992, 1992 IEEE NUCL SCI S, P942
[7]  
HARRISON RL, 1992, 1992 IEEE NUCL SCI S, P862
[8]   POSITRON EMISSION TOMOGRAPHY WITH A LARGE AXIAL ACCEPTANCE ANGLE - SIGNAL-TO-NOISE CONSIDERATIONS [J].
KARP, JS ;
KINAHAN, PE ;
MANKOFF, DA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :249-255
[9]   CROSS-PLANE SCATTERING CORRECTION - POINT-SOURCE DECONVOLUTION IN PET [J].
SHAO, LX ;
KARP, JS .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) :234-239
[10]   MEASURING PET SCANNER SENSITIVITY - RELATING COUNTRATES TO IMAGE SIGNAL-TO-NOISE RATIOS USING NOISE EQUIVALENT COUNTS [J].
STROTHER, SC ;
CASEY, ME ;
HOFFMAN, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (02) :783-788