APPLICATION OF THE DOT IMMUNOBINDING ASSAY TO ALLERGY DIAGNOSIS

被引:29
作者
DERER, MM
MIESCHER, S
JOHANSSON, B
FROST, H
GORDON, J
机构
[1] FRIEDRICH MIESCHER INST, CH-4002 BASEL, SWITZERLAND
[2] CIBA GEIGY AG, DIV PHARMACEUT, CH-4002 BASEL, SWITZERLAND
关键词
D O I
10.1016/0091-6749(84)90093-9
中图分类号
R392 [医学免疫学];
学科分类号
100102 ;
摘要
The recently developed dot immunobinding assay is operationally simple and facilitates performance of multiple simultaneous assays. Its use as the basis for determination of total and allergen-specific [human] IgE is established. For total IgE, the same commercially available polyclonal anti-human IgE was used on the solid phase and as a peroxidase conjugate in the liquid phase. After incubation with a chromogenic substrate, IgE was determined from the color intensity of the resulting dots with a scanning reflectance densitometer. The limit of sensitivity was 50 pg/ml of IgE. Standardized conditions gave the dynamic range 50-2500 IU/ml in serum. The IgE measured was not subject to interference by serum components, was labile at 56.degree. C, was soluble at 30% saturation (NH4)2SO4 and was unaffected by anti-human Ig of other specificity. Coefficients of variation were 0.05 within run, and were 0.1 between run. Comparison with data on sera obtained with the PRIST [paper radioimmunosorbent test] method yielded a correlation coefficient of 0.96 and a linear regression of slope 1.15. Assays for allergen-specific IgE were established with bee venom and dust mite allergens in the solid phase. The same peroxidase-conjugated antibody was used as for total IgE. Comparisons with comparable RAST [radioallergosorbent] assays were performed.
引用
收藏
页码:85 / 92
页数:8
相关论文
共 29 条
[1]   RADIOALLERGOSORBENT TEST - USES AND ABUSES [J].
ADKINSON, NF .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 1980, 65 (01) :1-4
[3]   PEROXIDASE LABELLED ANTIBODY AND FAB CONJUGATES WITH ENHANCED INTRACELLULAR PENETRATION [J].
AVRAMEAS, S ;
TERNYNCK, T .
IMMUNOCHEMISTRY, 1971, 8 (12) :1175-&
[4]   A SOLID-PHASE FLUOROIMMUNOASSAY FOR HUMAN IGE [J].
BLANCHARD, GC ;
GARDNER, RE .
JOURNAL OF IMMUNOLOGICAL METHODS, 1982, 52 (01) :81-90
[5]   MODIFIED SANDWICH TECHNIQUE FOR THE MEASUREMENT OF IGE [J].
BRUYNZEEL, PLB ;
HOUBEN, LAMJ ;
BERRENS, L .
CLINICA CHIMICA ACTA, 1979, 91 (01) :67-74
[6]   NEW AND SIMPLE RADIOIMMUNOASSAY METHOD FOR DETERMINATION OF IGE [J].
CESKA, M ;
LUNDKVIST, U .
IMMUNOCHEMISTRY, 1972, 9 (10) :1021-+
[7]  
CHAPMAN MD, 1980, J IMMUNOL, V125, P587
[8]  
GORDON J, UNPUB DIAGNOSTIC POT
[9]  
GORDON J, 1983, IMMUNOENZYMATIC TECH, P303
[10]  
HAWKES R, 1982, ANAL BIOCHEM, V119, P142, DOI 10.1016/0003-2697(82)90677-7