INTRACRANIAL ANEURYSMS AND VASCULAR MALFORMATIONS - COMPARISON OF TIME-OF-FLIGHT AND PHASE-CONTRAST MR ANGIOGRAPHY

被引:134
作者
HUSTON, J [1 ]
RUFENACHT, DA [1 ]
EHMAN, RL [1 ]
WIEBERS, DO [1 ]
机构
[1] MAYO CLIN & MAYO FDN,DEPT NEUROL,ROCHESTER,MN 55905
关键词
ANEURYSM; CEREBRAL; ARTERIOVENOUS MALFORMATIONS; CEREBRAL BLOOD VESSELS; MR STUDIES; MAGNETIC RESONANCE (MR); COMPARATIVE STUDIES; TECHNOLOGY;
D O I
10.1148/radiology.181.3.1947088
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Twenty-seven patients with 14 aneurysms and 17 vascular malformations were each examined with both time-of-flight (TF) and phase-contrast (PC) magnetic resonance angiography of the head. Three-dimensional (3D) PC imaging depicted the patent lumen of the aneurysms, while 3D TF imaging depicted the patent lumen and a subacute thrombus if present. The 3D PC techniques were superior to 3D TF methods in depicting aneurysms larger than 15 mm. PC angiography allowed velocity resolution of vascular lesions and yielded functional flow information by directly depicting collateral flow to vascular lesions. Artifacts present on TF images were due to substances with short Tl, hemosiderin, and surgical clips. Artifacts present on PC images were due to flow-related aliasing. The results showed that PC techniques have specific advantages over TF techniques, including identification of large aneurysms, velocity resolution of vascular lesions, depiction of flow direction about the circle of Willis, and less degradation by artifacts.
引用
收藏
页码:721 / 730
页数:10
相关论文
共 24 条
  • [1] ARTIFACTS IN MAXIMUM-INTENSITY-PROJECTION DISPLAY OF MR ANGIOGRAMS
    ANDERSON, CM
    SALONER, D
    TSURUDA, JS
    SHAPEERO, LG
    LEE, RE
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (03) : 623 - 629
  • [2] THE APPEARANCE OF RAPIDLY FLOWING BLOOD ON MAGNETIC-RESONANCE IMAGES
    BRADLEY, WG
    WALUCH, V
    LAI, KS
    FERNANDEZ, EJ
    SPALTER, C
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) : 1167 - 1174
  • [3] CHAKERES DW, 1990, AM J NEURORADIOL, V11, P1107
  • [4] MAGNETIC-RESONANCE ANGIOGRAPHY
    DUMOULIN, CL
    HART, HR
    [J]. RADIOLOGY, 1986, 161 (03) : 717 - 720
  • [5] 3-DIMENSIONAL PHASE-CONTRAST ANGIOGRAPHY
    DUMOULIN, CL
    SOUZA, SP
    WALKER, MF
    WAGLE, W
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 9 (01) : 139 - 149
  • [6] MAGNETIC-RESONANCE-IMAGING OF FLOW DYNAMICS IN THE CIRCLE OF WILLIS
    EDELMAN, RR
    MATTLE, HP
    OREILLY, GV
    WENTZ, KU
    LIU, C
    ZHAO, B
    [J]. STROKE, 1990, 21 (01) : 56 - 65
  • [7] MR ANGIOGRAPHY
    EDELMAN, RR
    MATTLE, HP
    ATKINSON, DJ
    HOOGEWOUD, HM
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 154 (05) : 937 - 946
  • [8] INTRACEREBRAL ARTERIOVENOUS-MALFORMATIONS - EVALUATION WITH SELECTIVE MR ANGIOGRAPHY AND VENOGRAPHY
    EDELMAN, RR
    WENTZ, KU
    MATTLE, HP
    OREILLY, GV
    CANDIA, G
    CHENG, L
    BIN, Z
    KJELLBERG, RN
    DAVIS, KR
    [J]. RADIOLOGY, 1989, 173 (03) : 831 - 837
  • [9] SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING
    FELMLEE, JP
    EHMAN, RL
    [J]. RADIOLOGY, 1987, 164 (02) : 559 - 564
  • [10] OCCULT CEREBRAL VASCULAR MALFORMATIONS - HIGH-FIELD MR IMAGING
    GOMORI, JM
    GROSSMAN, RI
    GOLDBERG, HI
    HACKNEY, DB
    ZIMMERMAN, RA
    BILANIUK, LT
    [J]. RADIOLOGY, 1986, 158 (03) : 707 - 713