ULTRA-THIN, HIGH-PRECISION FLEX CABLE FOR THE L3 SILICON MICROVERTEX DETECTOR

被引:14
作者
DIBITONTO, D
PENNINGTON, T
SUBHANI, K
AMBROSI, G
BIASINI, M
BABUCCI, E
BATTISTON, R
EASO, S
KRASTEV, V
PAULUZZI, M
SANTOCCHIA, A
BURGER, WJ
MATAY, G
机构
[1] UNIV PERUGIA, PERUGIA, ITALY
[2] UNIV GENEVA, GENEVA, SWITZERLAND
[3] TECH UNIV BUDAPEST, BUDAPEST, HUNGARY
关键词
D O I
10.1016/0168-9002(94)91323-4
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We describe an ultra-thin, high-precision Kapton flex cable for use as a signal router in the L3 Silicon Microvertex Detector. The excellent mechanical and electrical properties of this cable make it dimensionally stable against temperature and humidity changes, as well as maintaining cross talk below 3% between adjacent lines. Electron beam photolithography and chemical etching technology have produced a cable with typically 11 mu m wide lines spanning continuous lengths up to 14 cm, with sufficient alignment accuracy to match both input and output pads over the entire length of the detector. Electroplated input and output pads allow automated wire bonding with excellent pull strength and high efficiency.
引用
收藏
页码:404 / 412
页数:9
相关论文
共 6 条
  • [1] STATUS OF THE L3 SILICON MICROVERTEX DETECTOR
    ADRIANI, O
    AHLEN, S
    AMBROSI, G
    BABUCCI, E
    BARBAGLI, G
    BASCHIROTTO, A
    BATTISTON, R
    BAY, A
    BENCZE, G
    BENE, P
    BERTUCCI, B
    BIASINI, M
    BILEI, G
    BOISSEVAIN, JG
    BOSETTI, M
    BROOKS, ML
    BUSENITZ, J
    BURGER, WJ
    CAMPS, C
    CARIA, M
    CASTELLINI, G
    CASTELLO, R
    CHECCUCCI, B
    CHEN, A
    CHEN, WY
    COAN, TE
    COMMICHAU, V
    DIBITONTO, D
    EASO, S
    EXTERMANN, P
    FIANDRINI, E
    GOUGAS, A
    HANGARTER, K
    HAUVILLER, C
    HERVE, A
    HOFER, H
    KAPUSTINSKI, JS
    KINNISON, WW
    KIRST, H
    KRASTEV, VR
    LANDI, G
    LEBEAU, M
    LECOQ, P
    LEE, DM
    LEISTE, R
    LIN, W
    LOHMANN, W
    LUBELSMEYER, K
    MACDERMOTT, M
    MARIN, A
    [J]. NUCLEAR PHYSICS B, 1993, : 202 - 207
  • [2] ADRIANI O, UNPUB NUCL INSTR MET
  • [3] BAGLIESI G, INFNPIAE8610
  • [4] CHIPMAN P, COMMUNICATION
  • [5] Gupta K.C., 1979, MICROSTRIP LINES SLO
  • [6] SANTOCCHIA A, 1993, P M EXPT APPARATUS H