共 3 条
COMPUTED TOMOGRAPHY-GUIDED COIL INJECTION AND THORACOSCOPIC PULMONARY RESECTION UNDER ROENTGENOGRAPHIC FLUOROSCOPY
被引:48
作者:
ASAMURA, H
[1
]
KONDO, H
[1
]
NARUKE, T
[1
]
TSUCHIYA, R
[1
]
WAKAO, F
[1
]
KANEKO, M
[1
]
SUEMASU, K
[1
]
机构:
[1] NATL CANC CTR,DEPT ENDOSCOPY,CHUO KU,TOKYO 104,JAPAN
关键词:
D O I:
10.1016/0003-4975(94)91957-7
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
To remove a small, chest roentgenogram-negative, computed tomogram-positive nodule, we developed a novel technique of thoracoscopic pulmonary resection. This technique consists of the computed tomography-guided coil injection of a metallic coil and subsequent thoracoscopic resection under roentgenographic fluoroscopy. During the thoracoscopic resection, the fluoroscopic image was a valuable aid in determining the location of the nodule and in ensuring that the stapler was applied with a sufficient distance from the coil. Because this technique helps to determine the exact location of the nodule regardless of its depth from the pleural surface, even a minithoracotomy for direct palpation can be avoided.
引用
收藏
页码:1542 / 1544
页数:3
相关论文