MULTIPLANAR DISPLAY OF SPIRAL CT DATA OF THE PULMONARY HILA IN PATIENTS WITH LUNG-CANCER - PRELIMINARY-OBSERVATIONS

被引:15
作者
PADHANI, AR
FISHMAN, EK
HEITMILLER, RF
WANG, KP
WHEELER, JH
KUHLMAN, JE
机构
[1] JOHNS HOPKINS MED INST,RUSSELL H MORGAN DEPT RADIOL & RADIOL SCI,BALTIMORE,MD
[2] JOHNS HOPKINS MED INST,DEPT CARDIOTHORAC SURG,BALTIMORE,MD
[3] HARBOR HOSP CTR,BALTIMORE,MD
关键词
COMPUTED TOMOGRAPHY (CT); IMAGE QUALITY; COMPUTED TOMOGRAPHY; THORACIC; SPIRAL; LUNG NEOPLASMS;
D O I
10.1016/0899-7071(94)00059-L
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral or helical computed tomography (CT)-generated multiplanar reconstructions were used in the radiological assessment of the pulmonary hila in patients with central lung cancer. Twelve patients with non-small-cell lung cancer and hilar abnormalities were examined with contrast-enhanced spiral CT. Studies were performed on a Siemens Somatom S or Plus-S scanner using either a 24- or 32-second spiral. The study volume was from the arch of the aorta to the inferior pulmonary veins done in a single breath-hold, using 4-mm collimation, and reconstructed at 2-mm intervals. We assessed the quality of vascular enhancement and of multiplanar reconstructions. Bronchoscopic, surgical, and pathological findings were correlated. Excellent vascular opacification and good-quality reconstructions were obtained in all patients. No interscan motion was detected. No problems were encountered with the breathholding technique or in the reconstruction of images, even in patients with poor respiratory function. Multiplanar reconstructions were useful for the evaluation of mediastinal including vascular and airways invasion, for optimal definition of lymph node groups, for the planning of bronchoscopically guided biopsy, as well as for endobronchoscopic laser coagulation therapy and surgical treatment. Spiral CT-generated multiplanar reconstructions of the hila are helpful for staging, solving problems, guiding bronchoscopy, and planning surgery. Even patients with limited respiratory reserve can successfully complete the examination.
引用
收藏
页码:252 / 257
页数:6
相关论文
共 14 条
[1]   CT DEMONSTRATION OF PROMINENT RIGHT HILAR SOFT-TISSUE COLLECTIONS [J].
ASHIDA, C ;
ZERHOUNI, EA ;
FISHMAN, EK .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1987, 11 (01) :57-59
[2]   PULMONARY NODULE - EVALUATION WITH SPIRAL VOLUMETRIC CT [J].
COSTELLO, P ;
ANDERSON, W ;
BLUME, D .
RADIOLOGY, 1991, 179 (03) :875-876
[3]   SPIRAL CT OF THE THORAX WITH REDUCED VOLUME OF CONTRAST MATERIAL - A COMPARATIVE-STUDY [J].
COSTELLO, P ;
DUPUY, DE ;
ECKER, CP ;
TELLO, R .
RADIOLOGY, 1992, 183 (03) :663-666
[4]   SPIRAL CT OF THE PANCREAS WITH MULTIPLANAR DISPLAY [J].
FISHMAN, EK ;
WYATT, SH ;
NEY, DR ;
KUHLMAN, JE ;
SIEGELMAN, SS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) :1209-1215
[5]   SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION [J].
KALENDER, WA ;
SEISSLER, W ;
KLOTZ, E ;
VOCK, P .
RADIOLOGY, 1990, 176 (01) :181-183
[6]  
KITAOKA H, 1991, Nippon Acta Radiologica, V51, P516
[7]  
Miyamoto H, 1989, Kokyu To Junkan, V37, P1209
[8]   3-DIMENSIONAL VOLUMETRIC DISPLAY OF CT DATA - EFFECT OF SCAN PARAMETERS UPON IMAGE QUALITY [J].
NEY, DR ;
FISHMAN, EK ;
MAGID, D ;
ROBERTSON, DD ;
KAWASHIMA, A .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) :875-885
[9]   3-DIMENSIONAL CT-VOLUMETRIC RECONSTRUCTION AND DISPLAY OF THE BRONCHIAL TREE [J].
NEY, DR ;
KUHLMAN, JE ;
HRUBAN, RH ;
REN, H ;
HUTCHINS, GM ;
FISHMAN, EK .
INVESTIGATIVE RADIOLOGY, 1990, 25 (06) :736-742
[10]  
NEY DR, 1989, RADIOLOGY, V170, P875