FABRICATION OF COLUMNS FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY USING PHOTOPOLYMERIZATION OF ACRYLATES

被引:19
作者
EGUCHI, S
KLOOSTERBOER, JG
ZEGERS, CPG
SCHOENMAKERS, PJ
TOCK, PPH
KRAAK, JC
POPPE, H
机构
[1] PHILIPS RES LABS,POB 80000,5600 JA EINDHOVEN,NETHERLANDS
[2] UNIV AMSTERDAM,ANALYT CHEM LAB,1018 WV AMSTERDAM,NETHERLANDS
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 516卷 / 02期
关键词
D O I
10.1016/S0021-9673(01)89272-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In liquid chromatography, a significant improvement of separation can be achieved by using 5-10-μm I.D. open capillaries instead of packed columns. In these capillaries relatively thick (0.3-2 μm) films of stationary phases are required. These are difficult to prepare if polymer solutions are to be used. The fabrication of thick polymer films inside quartz-glass capillaries using chain cross-linking photopolymerization of monomers in liquid solution rather than cross-linking of polymers cast from solution is described. In a 9-μm capillary a film thickness of about 0.3 μm was readily prepared and plate numbers of 7 · 104 to 1.2 · 105 m-1 were obtained. The photopolymerization process can be carried out under either static or dynamic conditions. The latter method facilitates the manufacture of long columns with a length of several metres. The experimental conditions for making smooth coatings using a siloxane acrylate together with lauryl acrylate as a reactive diluent, and methods for inspection and testing of these columns, are described. © 1990.
引用
收藏
页码:301 / 312
页数:12
相关论文
共 24 条
[1]  
ADAMSON AW, 1967, PHYSICAL CHEMISTRY S, pCH1
[2]   RAYLEIGH INSTABILITY OF STATIONARY PHASE FILMS IN CAPILLARY COLUMN CHROMATOGRAPHY [J].
BARTLE, KD ;
WOOLLEY, CL ;
MARKIDES, KE ;
LEE, ML ;
HANSEN, RS .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (03) :128-136
[3]  
Chynoweth A. B., 1979, OPTICAL FIBER TELECO
[4]   PHOTOIONIZATION DETECTOR FOR OPEN-TUBULAR LIQUID-CHROMATOGRAPHY [J].
DEWIT, JSM ;
JORGENSON, JW .
JOURNAL OF CHROMATOGRAPHY, 1987, 411 :201-212
[5]   NEW METHOD FOR THE PREPARATION OF SMALL DIAMETER COLUMNS WITH POLYMERIC STATIONARY PHASES FOR OPEN TUBULAR LIQUID-CHROMATOGRAPHY [J].
DLUZNESKI, PR ;
JORGENSON, JW .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1988, 11 (04) :332-336
[6]   POLYMERIZED STATIONARY PHASES IN 12 TO 50-MU-M OPEN TUBULAR FUSED-SILICA COLUMNS FOR LC AND GC [J].
FARBROT, A ;
FOLESTAD, S ;
LARSSON, M .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (02) :117-119
[7]   SWOLLEN POLYSILOXANES AS STATIONARY PHASES IN REVERSED-PHASE OPEN-TUBULAR COLUMN LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 394 (03) :455-464
[8]   PERFORMANCE AND PREPARATION OF IMMOBILIZED POLYSILOXANE STATIONARY PHASES IN 5-55 MU-M ID OPEN-TUBULAR FUSED-SILICA COLUMNS FOR LIQUID-CHROMATOGRAPHY [J].
FOLESTAD, S ;
JOSEFSSON, B ;
LARSSON, M .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (02) :347-372
[9]   LIQUID-CHROMATOGRAPHY IN OPEN-TUBULAR COLUMNS - THEORY OF COLUMN OPTIMIZATION WITH LIMITED PRESSURE AND ANALYSIS TIME, AND FABRICATION OF CHEMICALLY BONDED REVERSED-PHASE COLUMNS ON ETCHED BOROSILICATE GLASS-CAPILLARIES [J].
JORGENSON, JW ;
GUTHRIE, EJ .
JOURNAL OF CHROMATOGRAPHY, 1983, 255 (JAN) :335-348
[10]   PNEUMATIC MICROSYRINGE FOR USE AS AN INJECTOR IN OPEN TUBULAR LIQUID-CHROMATOGRAPHY AND AS A DISPENSER IN MICROANALYSIS [J].
KENNEDY, RT ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1988, 60 (15) :1521-1524