THE ISOMETRIC LENGTH FORCE MODELS OF 9 DIFFERENT SKELETAL-MUSCLES

被引:66
作者
GAREIS, H [1 ]
SOLOMONOW, M [1 ]
BARATTA, R [1 ]
BEST, R [1 ]
DAMBROSIA, R [1 ]
机构
[1] LOUISIANA STATE UNIV,MED CTR,DEPT ORTHOPAED SURG,BIOENGN LAB,2025 GRAVIER ST,NEW ORLEANS,LA 70112
关键词
D O I
10.1016/0021-9290(92)90230-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The length-force relations of nine different skeletal muscles in the hindlimb of the cat were determined experimentally, with electrical stimulation of the sciatic nerve as the activation mode. It was shown that the active-, passive-, and total-force patterns varied widely among the muscles. The tibialis posterior (TP) medial and lateral gastrocnemius (MG, LG) and flexor digitorum longus (FDL) had a symmetric active-force curve, whereas the tibialis anterior (TA), peroneus brevis (PB), peroneus longus (PL), extensor digitorum longus (EDL), and soleus (SOL) had an asymmetric curve which exhibits about 25% of the maximal isometric force at extreme lengths. The SOL, EDL, and LG had a low-level passive force which appeared at short muscle length, whereas all other muscles exhibited initial passive force just before the optimal length. The total force was rising quasi-linearly for the SOL, whereas the other muscles exhibited an intermediate plateau about the optimal length. The LG and FDL had a substantial but temporary intermediate dip in the total force as the muscle was elongated past the optimal length. The elongation range of the various muscles also varied, ranging from +/- 15 to +/- 30% of the optimal length. The elongation range was symmetric for the FDL, LG, MG, TP, SOL, and EDL, and asymmetric for thc PL, PB, and TA, being - 12 to + 17%, - 12 to + 17%, and - 35 to + 12%, respectively. Two different models which incorporate muscle architecture were successfully fitted to the experimental data of the muscles except for the MG and TA. The architecture of these two muscles is highly nonhomogeneous and contains compartments with two pennation patterns or two different optimal lengths. New models, which add spatially and temporally the individual characteristics of each compartment of the muscles, were constructed for these two muscles. The new models demonstrated high correlation to the experimental data obtained from the MG and TA. It was concluded that the length-force relation varies widely among various skeletal muscles and is probably dependent on the primary function of the muscle in the context of integrated movement; this is a manifestation of architectural factors such as fiber pennation pattern and angle, cross-sectional area, ratio of muscle to tendon length, distribution of the fiber length within the muscle and compartmental pennation.
引用
收藏
页码:903 / 916
页数:14
相关论文
共 27 条
[1]   HINDLIMB MUSCLE FIBER POPULATIONS OF 5 MAMMALS [J].
ARIANO, MA ;
ARMSTRONG, RB ;
EDGERTON, VR .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1973, 21 (01) :51-55
[2]   ISOMETRIC CONTRACTIONS OF MOTOR UNITS IN A FAST TWITCH MUSCLE OF CAT [J].
BAGUST, J ;
KNOTT, S ;
LEWIS, DM ;
LUCK, JC ;
WESTERMAN, RA .
JOURNAL OF PHYSIOLOGY-LONDON, 1973, 231 (01) :87-104
[3]   FREQUENCY-RESPONSE MODEL OF SKELETAL-MUSCLE - EFFECT OF PERTURBATION LEVEL, AND CONTROL STRATEGY [J].
BARATTA, R ;
ZHOU, BH ;
SOLOMONOW, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1989, 27 (04) :337-345
[4]   DYNAMIC PERFORMANCE OF A LOAD-MOVING SKELETAL-MUSCLE [J].
BARATTA, R ;
SOLOMONOW, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1991, 71 (02) :749-757
[5]   THE EFFECT OF TENDON VISCOELASTIC STIFFNESS ON THE DYNAMIC PERFORMANCE OF ISOMETRIC MUSCLE [J].
BARATTA, R ;
SOLOMONOW, M .
JOURNAL OF BIOMECHANICS, 1991, 24 (02) :109-116
[6]   THE DYNAMIC-RESPONSE MODEL OF 9 DIFFERENT SKELETAL-MUSCLES [J].
BARATTA, R ;
SOLOMONOW, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (03) :243-251
[7]  
BLIX M, 1891, SCAND ARCH PHYSL, V3, P295
[8]  
Blix M, 1894, SKAND ARCH PHYSL, V5, P149
[9]  
Blix M., 1893, SKANDINAVISCHES ARCH, V4, P399
[10]   THE FORCE-LENGTH RELATIONSHIP OF A MUSCLE-TENDON COMPLEX - EXPERIMENTAL RESULTS AND MODEL-CALCULATIONS [J].
BOBBERT, MF ;
ETTEMA, GC ;
HUIJING, PA .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1990, 61 (3-4) :323-329