AN AUTOMATED-METHOD FOR THE ANALYSIS OF TRABECULAR BONE-STRUCTURE

被引:31
作者
AARON, JE [1 ]
JOHNSON, DR [1 ]
KANIS, JA [1 ]
OAKLEY, BA [1 ]
OHIGGINS, P [1 ]
PAXTON, SK [1 ]
机构
[1] UNIV SHEFFIELD,DEPT HUMAN METAB & CLIN BIOCHEM,SHEFFIELD S10 2TN,S YORKSHIRE,ENGLAND
来源
COMPUTERS AND BIOMEDICAL RESEARCH | 1992年 / 25卷 / 01期
基金
英国医学研究理事会;
关键词
D O I
10.1016/0010-4809(92)90031-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Trabecular structure as well as bone mass is important in studies of bone disease and fracture. An automated method for the direct analysis of two-dimensional trabecular microanatomy and its application to human iliac crest bone biopsies is described. Compared with established methods which require expensive equipment and complex software, costs have been reduced and availability increased by using an image analyzer driven by a microcomputer. Routine histological sections are accepted and an editing function enables the removal of artifacts. An elastic window allows field expansion for large specimens. The program enables the rapid assessment of the bone volume and trabecular surface from the intact image, followed by image skeletonization and the deduction of the trabecular length, number, character, and spacing together with the number of trabecular junctions and discontinuities; the trabecular width is calculated indirectly. Images may be stored to disk or printed as permanent records for diagnostic or research purposes. © 1992.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 28 条
[1]  
AARON JE, 1987, CLIN ORTHOPAEDICS, V215, P260
[2]  
AARON JE, 1989, CLIN ORTHOP RELAT R, V243, P294
[3]  
AARON JE, 1976, CALCIUM PHOSPHATE MA, P566
[4]  
AARON JE, IN PRESS BONE MINER
[5]   MEASUREMENT OF ANISOTROPIC VERTEBRAL TRABECULAR BONE LOSS DURING AGING BY QUANTITATIVE IMAGE-ANALYSIS [J].
BERGOT, C ;
LAVALJEANTET, AM ;
PRETEUX, F ;
MEUNIER, A .
CALCIFIED TISSUE INTERNATIONAL, 1988, 43 (03) :143-149
[6]  
BIRKENHAGERFREN.DH, 1985, BONE, V6, P401
[7]  
BIRKENHAGERFRENKEL DH, 1988, BONE MINER, V4, P197
[8]   AGE-RELATED-CHANGES IN ILIAC CREST TRABECULAR MICROANATOMIC BONE-STRUCTURE IN MAN [J].
COMPSTON, JE ;
MELLISH, RWE ;
GARRAHAN, NJ .
BONE, 1987, 8 (05) :289-292
[9]   SEMIAUTOMATIC IMAGE-ANALYSIS APPLIED TO THE QUANTIFICATION OF BONE MICROSTRUCTURE [J].
DALLANT, P ;
MEUNIER, A ;
CHRISTEL, PS ;
SEDEL, L .
JOURNAL OF BIOMEDICAL ENGINEERING, 1986, 8 (04) :320-328
[10]   THE DIRECT EXAMINATION OF 3-DIMENSIONAL BONE ARCHITECTURE INVITRO BY COMPUTED-TOMOGRAPHY [J].
FELDKAMP, LA ;
GOLDSTEIN, SA ;
PARFITT, AM ;
JESION, G ;
KLEEREKOPER, M .
JOURNAL OF BONE AND MINERAL RESEARCH, 1989, 4 (01) :3-11