ACCEPTANCE AND USE OF THE SMPTE MEDICAL DIAGNOSTIC-IMAGING TEST PATTERN FOR TELEVISION MONITORS AND HARD-COPY RECORDING CAMERAS

被引:5
作者
GRAY, JE
LISK, KG
ANDERSON, W
HARSHBARGER, JH
SCHWENKER, R
UZENOFF, RA
机构
[1] EASTMAN KODAK CO, ROCHESTER, NY 14650 USA
[2] THREE M CO, ST PAUL, MN 55144 USA
[3] VII INC, XENIA, OH 45385 USA
[4] DUPONT CO, WILMINGTON, DE 19898 USA
[5] FUJI MED SYST, STAMFORD, CT 06907 USA
来源
SMPTE JOURNAL | 1990年 / 99卷 / 12期
关键词
D O I
10.5594/J02540
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In 1986 the SMPTE published a Recommended Practice (RP 133) specifying a test pattern for medical imaging applications, which has enjoyed wide acceptance in the medical imaging community. Use of the test pattern for acceptance testing, video monitor and image recording device setup, and quality control is described, and examples of problems detected with it are presented. The use of this test pattern for laser camera (printer) applications is also discussed.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 4 条
[1]  
BRONSKILL MJ, 1984, P SOC PHOTO-OPT INST, V486, P180, DOI 10.1117/12.943217
[2]   THE CATHODE-RAY TUBE (CRT) AS A SOURCE OF GRAINY CT IMAGES [J].
GRAY, JE ;
WINKLER, NT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (05) :1100-1101
[3]   TEST PATTERN FOR VIDEO DISPLAYS AND HARD-COPY CAMERAS [J].
GRAY, JE ;
LISK, KG ;
HADDICK, DH ;
HARSHBARGER, JH ;
OOSTERHOF, A ;
SCHWENKER, R .
RADIOLOGY, 1985, 154 (02) :519-527
[4]  
1986, SMPTE J, V95, P693