AMPEROMETRIC GLUCOSE SENSORS BASED ON IMMOBILIZED GLUCOSE-OXIDASE POLYQUINONE SYSTEM

被引:78
作者
KAKU, T
KARAN, HI
OKAMOTO, Y
机构
[1] POLYTECH INST NEW YORK,DEPT CHEM,BROOKLYN,NY 11201
[2] POLYTECH INST NEW YORK,POLYMER RES INST,BROOKLYN,NY 11201
[3] CUNY MEDGAR EVERS COLL,DEPT PHYS SCI & COMP SCI,BROOKLYN,NY 11225
关键词
D O I
10.1021/ac00080a006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Non-cross-linked and also cross-linked poly(ether amine quinone)s were prepared and tested for their efficiency as electron-transfer relay systems in amperometric glucose biosensors. Cyclic voltammetry and constant applied potential measurements showed that poly(ether amine quinone) relay systems efficiently mediated electron transfer from reduced glucose oxidase to a conventional carbon paste electrode. Sensors containing these relay systems respond rapidly to low (<0.1 mM) glucose concentrations and reach steady-state current responses in less than 1 min. Electrodes constructed with cross-linked polymer and glucose oxidase were stable, indicating that the glucose oxidase was trapped in the polymer matrix and did not freely diffuse away from the electrode surface into aqueous solutions. The cross-linked polymer is a large molecular system which facilitates a flow of electrons from enzyme to the electrode, acting as an electron-transfer relay system and not as a diffusional mediator.
引用
收藏
页码:1231 / 1235
页数:5
相关论文
共 33 条
  • [1] ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE
    BELANGER, D
    NADREAU, J
    FORTIER, G
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) : 143 - 155
  • [2] FERROCENE-MEDIATED ENZYME ELECTRODE FOR AMPEROMETRIC DETERMINATION OF GLUCOSE
    CASS, AEG
    DAVIS, G
    FRANCIS, GD
    HILL, HAO
    ASTON, WJ
    HIGGINS, IJ
    PLOTKIN, EV
    SCOTT, LDL
    TURNER, APF
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (04) : 667 - 671
  • [3] BIOELECTROCATALYTIC CONVERSION OF SUBSTANCES ON POLYMER-MODIFIED ELECTRODES
    CENAS, NK
    POCIUS, AK
    KULYS, JJ
    [J]. BIOELECTROCHEMISTRY AND BIOENERGETICS, 1984, 12 (5-6): : 583 - 591
  • [4] Clark L. C., 1987, BIOSENSORS FUNDAMENT
  • [5] ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
    CLARK, LC
    LYONS, C
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1962, 102 (01) : 29 - &
  • [6] ELECTRICAL COMMUNICATION BETWEEN REDOX CENTERS OF GLUCOSE-OXIDASE AND ELECTRODES VIA ELECTROSTATICALLY AND COVALENTLY BOUND REDOX POLYMERS
    DEGANI, Y
    HELLER, A
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1989, 111 (06) : 2357 - 2358
  • [7] PROPAGATION OF A REDOX REACTION THROUGH A QUINOID POLYMER FILM ON AN ELECTRODE
    FUKUI, M
    KITANI, A
    DEGRAND, C
    MILLER, LL
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (01) : 28 - 33
  • [8] A GLUCOSE ELECTRODE BASED ON CARBON PASTE CHEMICALLY MODIFIED WITH A FERROCENE-CONTAINING SILOXANE POLYMER AND GLUCOSE-OXIDASE, COATED WITH A POLY(ESTER-SULFONIC ACID) CATION-EXCHANGER
    GORTON, L
    KARAN, HI
    HALE, PD
    INAGAKI, T
    OKAMOTO, Y
    SKOTHEIM, TA
    [J]. ANALYTICA CHIMICA ACTA, 1990, 228 (01) : 23 - 30
  • [9] CROSS-LINKED REDOX GELS CONTAINING GLUCOSE-OXIDASE FOR AMPEROMETRIC BIOSENSOR APPLICATIONS
    GREGG, BA
    HELLER, A
    [J]. ANALYTICAL CHEMISTRY, 1990, 62 (03) : 258 - 263
  • [10] Hale P. D., 1990, BIOSENSOR TECHNOLOGY