ANTHROPOMETRIC ESTIMATION OF NEONATAL BODY-COMPOSITION

被引:174
作者
CATALANO, PM
THOMAS, AJ
AVALLONE, DA
AMINI, SB
机构
[1] Department of Reproductive Biology, Case Western Reserve University, MetroHealth Medical Center Cleveland, OH
关键词
NEONATAL BODY COMPOSITION; TOTAL BODY ELECTRICAL CONDUCTIVITY; ANTHROPOMETRY;
D O I
10.1016/0002-9378(95)91348-3
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
OBJECTIVE: Estimation of neonatal body composition can be useful in the understanding of fetal growth. However, body composition methods such as total body water and total body electric conductivity are expensive and not readily available. Our primary purpose was to develop an anthropometric model to estimate neonatal body composition and prospectively validate the model against total body electric conductivity and secondarily to compare our anthropometric model and a previously published anthropometric formula with total body electric conductivity. STUDY DESIGN: A total of 194 neonates had estimates of body composition according to total body electric conductivity (group 1). Parental morphometrics, gestational age, race, sex, parity, and neonatal measurements including birth weight, length, head circumference, and skinfolds (triceps, subscapular, flank, acid thigh) were correlated with body fat by use of stepwise regression analysis. The model was validated in a second group of 65 neonates (group 2). RESULTS: There were no significant differences in any of the parental or neonatal measurements between groups 1 and 2. In group 1, 78% of the variance in body fat with the use of total body electric conductivity was explained by birth weight, length, and flank skinfold (R(2) = 0.78, p = 0.0001). When prospectively validated by the subjects in group 2, the model had significant and stronger correlation (R(2) = 0.84, p = 0.0001) with body fat estimated by total body electric conductivity as compared with the other anthropometric model (R(2) = 0.54, p = 0.0001). There was no significant (p = 0.11) difference between our anthropometric estimate of body fat and total body electric conductivity. CONCLUSIONS: The anthropometric model developed can be used to reasonably predict neonatal body fat mass at birth.
引用
收藏
页码:1176 / 1181
页数:6
相关论文
共 13 条
  • [1] AMINI SB, 1994, OBSTET GYNECOL, V83, P342
  • [2] MATERNAL CARBOHYDRATE-METABOLISM AND ITS RELATIONSHIP TO FETAL GROWTH AND BODY-COMPOSITION
    CATALANO, PM
    DRAGO, NM
    AMINI, SB
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1995, 172 (05) : 1464 - 1470
  • [3] CATALANO PM, 1992, OBSTET GYNECOL, V79, P46
  • [4] ASSESSMENT OF TOTAL-BODY FAT IN INFANCY FROM SKINFOLD THICKNESS MEASUREMENTS
    DAUNCEY, MJ
    GANDY, G
    GAIRDNER, D
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 1977, 52 (03) : 223 - 227
  • [5] TOTAL-BODY ELECTRICAL-CONDUCTIVITY MEASUREMENTS IN THE NEONATE
    FIOROTTO, ML
    KLISH, WJ
    [J]. CLINICS IN PERINATOLOGY, 1991, 18 (03) : 611 - 627
  • [6] TOTAL-BODY ELECTRICAL-CONDUCTIVITY MEASUREMENTS - AN EVALUATION OF CURRENT INSTRUMENTATION FOR INFANTS
    FIOROTTO, ML
    DEBRUIN, NC
    BRANS, YW
    DEGENHART, HJ
    VISSER, HKA
    [J]. PEDIATRIC RESEARCH, 1995, 37 (01) : 94 - 100
  • [7] FIOROTTO ML, 1991, FASEB J, V5, pA925
  • [8] FIOROTTO ML, 1987, AM J PHYSIOL, V252, pR798
  • [9] FORBES GB, 1962, PEDIATRICS, V29, P477
  • [10] McGowan A., 1975, Biology of the Neonate, V25, P66