PHYSICAL DETERMINANTS OF THE ENDOCARDIAL P-WAVE

被引:20
作者
SHANDLING, AH
FLORIO, J
CASTELLANET, MJ
MESSENGER, JC
CRUMP, R
EVANS, K
RYLAARSDAM, A
NOLASCO, M
机构
[1] UNIV CALIF IRVINE,IRVINE,CA 92717
[2] PACESETTER SYST INC,SYLMAR,CA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1990年 / 13卷 / 12期
关键词
ATRIAL SENSING; P-WAVE; FAR-FIELD R-WAVE; PACEMAKER; RESPIRATION; BODY POSITION; SLEW RATE;
D O I
10.1111/j.1540-8159.1990.tb06858.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Reliable atrial sensing of intrinsic P wave activity is important to ensure optimal atrial or dual chamber pacemaker function. Various physical factors (e.g., posture, respiration, exercise) may influence P wave characteristics and impair adequate sensing. To investigate this phenomenon, we measured the average of three P wave amplitudes (PWA) and calculated slew rates from telemetered printouts acquired from Pacesetter pacemakers in 32 patients. These measurements were performed in various body positions, with upright exercise and in varying stages of respiration. Results: the mean supine PWA increased on full inspiration (3.56 +/- 1.3 mV versus 3.25 +/- 1.2 mV during quiet respiration, P < 0.001), and also increased significantly with full expiration. The mean PWA increased on assuming the erect position (3.25 +/- 1.2 mV increasing to 3.49 +/- 1.3 mV, P < 0.001); in the upright position, the mean erect PWA during quiet respiration was not significantly influenced by the stage of respiration. The mean upright exercise PWA did not differ significantly from the preexercise erect PWA (3.50 +/- 1.2 with exercise, and 3.47 +/- 1.5 before exercise; P = NS). Calculated slew rates were not different lying versus standing. Conclusions: the mean supine PWA increases significantly at the extremes of respiration and on assuming the erect body position; upright exercise results in no appreciable change in the erect PWA. Atrial sensitivity adjustments based on standard supine testing should be adequate for all body positions.
引用
收藏
页码:1585 / 1589
页数:5
相关论文
共 13 条
[1]  
ALONSOPULPON L, 1985, CARDIAC PACING ELECT, P1125
[2]  
DECAPRIO V, 1976, MED INSTRUM, V10, P55
[3]  
ELLESTAD MH, 1986, STRESS TESTING PRINC, P187
[4]   DIAGNOSTIC IMPLICATIONS OF ATRIAL VULNERABILITY [J].
ENGEL, TR ;
LUCK, JC ;
LEDDY, CL ;
DELCGONZALEZ, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (02) :208-214
[5]   SENSOR-MODULATED DUAL CHAMBER CARDIAC PACING - TOO MUCH OF A GOOD THING TOO FAST [J].
FEUER, JM ;
SHANDLING, AH ;
ELLESTAD, MH .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1990, 13 (06) :816-818
[6]   ATRIAL SENSING PERFORMANCE OF AV UNIVERSAL PACEMAKERS DURING EXERCISE [J].
FROHLIG, G ;
BLANK, W ;
SCHWERDT, H ;
SEN, S ;
BETTE, L .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (01) :47-60
[7]   ATRIAL SIGNAL VARIATIONS AND PACEMAKER MALSENSING DURING EXERCISE - A STUDY IN THE TIME AND FREQUENCY-DOMAIN [J].
FROHLIG, G ;
SCHWERDT, H ;
SCHIEFFER, H ;
BETTE, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1988, 11 (04) :806-813
[8]   ATRIAL-FIBRILLATION DURING AV SEQUENTIAL PACING [J].
FURMAN, S ;
COOPER, JA .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1982, 5 (01) :133-135
[9]   CARDIAC PACING AND PACEMAKERS .3. SENSING CARDIAC ELECTROGRAM [J].
FURMAN, S ;
HURZELER, P ;
DECAPRIO, V .
AMERICAN HEART JOURNAL, 1977, 93 (06) :794-801
[10]   ATRIAL FIBRILLATION PRODUCED BY ATRIAL STIMULATION [J].
HAFT, JI ;
LAU, SH ;
STEIN, E ;
KOSOWSKY, BD ;
DAMATO, AN .
CIRCULATION, 1968, 37 (01) :70-&