OPTIMIZATION OF CARDIAC DEFIBRILLATION BY 3-DIMENSIONAL FINITE-ELEMENT MODELING OF THE HUMAN THORAX

被引:49
作者
PANESCU, D
WEBSTER, JG
TOMPKINS, WJ
STRATBUCKER, RA
机构
[1] UNIV WISCONSIN,DEPT ELECT ENGN,MADISON,WI 53706
[2] RADIAT HLTH CTR STATE NEBRASKA,OMAHA,NE 68152
[3] UNIV WISCONSIN,DEPT ELECT & COMP ENGN,MADISON,WI 53706
关键词
D O I
10.1109/10.341831
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The goal of this study was to determine the optimal electrode placement and size to minimize myocardial damage during defibrillation while rendering refractory a critical mass of cardiac tissue of 100%. For this purpose, we developed a 3-D finite element model with 55 388 nodes, 50 913 hexahedral elements, and simulated 16 different organs and tissues, as well as the properties of the electrolyte. The model used a nonuniform mesh with an average spatial resolution of 0.8 cm in all three dimensions. To validate this model, we measured the voltage across 3-cm(2) Ag-AgCl electrodes when currents of 5 mA at 50 kHz were injected into a human subject's thorax through the same electrodes. For the same electrode placements and sizes and the same injected current, the finite element analysis produced results in good agreement with the experimental data. For the optimization of defibrillation, we tested 12 different electrode placements and seven different electrode sizes. The finite element analyses showed that the anterior-posterior electrode placement and an electrode size of about 90 cm(2) offered the least chance of potential myocardial damage and required a shock energy of less than 350 J for 5-ms defibrillation pulses to achieve 100% critical mass. For comparison, the average cross-sectional area of the heart is approximate to 48 cm(2), about half of the optimal area. A second best electrode placement was with the defibrillation electrodes on the midaxillary lines under the armpits. Although this placement had higher chances of producing cardiac damage, it required less shock energy to achieve 100% critical mass.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 47 条
  • [1] AHMED M, 1991, P ANN INT C IEEE ENG, V13, P776
  • [2] [Anonymous], 1971, ITERATIVE SOLUTION L
  • [3] BILLIE DE, 1992, P ANN INT C IEEE ENG, V14, P653
  • [4] BROWN BE, 1984, TAURUS INTERACTIVE P
  • [5] CHRISTAN MA, 1992, INGRID 3D MESH GENER
  • [6] A VOLUME CONDUCTOR MODEL OF THE THORAX FOR THE STUDY OF DEFIBRILLATION FIELDS
    CLAYDON, FJ
    PILKINGTON, TC
    TANG, ASL
    MORROW, MN
    IDEKER, RE
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (11) : 981 - 992
  • [7] MYOCARDIAL NECROSIS FROM DIRECT-CURRENT COUNTERSHOCK - EFFECT OF PADDLE ELECTRODE SIZE AND TIME INTERVAL BETWEEN DISCHARGES
    DAHL, CF
    EWY, GA
    WARNER, ED
    THOMAS, ED
    [J]. CIRCULATION, 1974, 50 (05) : 956 - 961
  • [8] DAVIS JS, 1975, C CARDIAC DEFIBRILLA, P27
  • [9] CARDIAC DAMAGE PRODUCED BY DIRECT-CURRENT COUNTER-SHOCK APPLIED TO THE HEART
    DOHERTY, PW
    MCLAUGHLIN, PR
    BILLINGHAM, M
    KERNOFF, R
    GORIS, ML
    HARRISON, DC
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1979, 43 (02) : 225 - 232
  • [10] Duff Iain S., 1990, DIRECT METHODS SPARS