PROTOCOL FOR 2-DIMENSIONAL MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY STUDIED IN 3-DIMENSIONAL MAGNETIC-RESONANCE DATA SETS

被引:23
作者
POST, JC
VANROSSUM, AC
HOFMAN, MBM
VALK, J
VISSER, CA
机构
[1] FREE UNIV AMSTERDAM HOSP,DEPT CLIN PHYS & ENGN,1081 HV AMSTERDAM,NETHERLANDS
[2] FREE UNIV AMSTERDAM HOSP,DEPT RADIOL,1081 HV AMSTERDAM,NETHERLANDS
[3] FREE UNIV AMSTERDAM,CARDIOVASC RES INST,AMSTERDAM,NETHERLANDS
[4] INTERUNIV CARDIOL INST NETHERLANDS,UTRECHT,NETHERLANDS
关键词
D O I
10.1016/0002-8703(95)90252-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to develop a standardized method of 2D MRA of the proximal 50 mm of the major epicardial coronary arteries. Therefore the efficacy of fixed imaging planes (transverse, coronal, sagittal, 30-degree RAO equivalent, and 60-degree LAO equivalent) in imaging coronary arteries was compared to that of oblique planes defined by the operator on a previously obtained image. 3D data sets obtained by a respiratory-gated 3D MRA method in eight patients with a mean age of 57 years were studied by multiplanar reformatting. Efficacy of planes was expressed as an IOE. Fixed transverse imaging planes proved to be equally efficacious as operator-defined planes in imaging the left main (IOE 2.2 ± 1.0 vs 2.2 ± 0.9, p = NS) and LAD (IOE 6.0 ± 1.9 vs 8.2 ± 2.0, p = NS). Operator-defined planes were superior to fixed imaging planes in imaging the RCA (IOE 6.3 ± 1.2 vs 3.5 ± 1.2, p < 0.001) and the LCx (IOE 6.2 ± 2.3 vs 4.8 < 2.3, p < 0.05). On the basis of these results, a standardized 2D MRA protocol for the proximal coronary arteries was proposed. Pitfalls in interpretation of coronary MRA images were discussed. © 1995.
引用
收藏
页码:167 / 173
页数:7
相关论文
共 12 条
  • [1] A NEW MACROMOLECULE AS A CONTRAST AGENT FOR MR-ANGIOGRAPHY - PREPARATION, PROPERTIES, AND ANIMAL STUDIES
    BOGDANOV, AA
    WEISSLEDER, R
    FRANK, HW
    BOGDANOVA, AV
    NOSSIF, N
    SCHAFFER, BK
    TSAI, E
    PAPISOV, MI
    BRADY, TJ
    [J]. RADIOLOGY, 1993, 187 (03) : 701 - 706
  • [2] NMR ANGIOGRAPHY OF CORONARY VESSELS WITH 2-D PLANAR IMAGE SCANNING
    CHO, ZH
    MUN, CW
    FRIEDENBERG, RM
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1991, 20 (01) : 134 - 143
  • [3] CORONARY-ARTERY IMAGING IN MULTIPLE 1-SEC BREATH HOLDS
    DOYLE, M
    SCHEIDEGGER, MB
    DEGRAAF, RG
    VERMEULEN, J
    POHOST, GM
    [J]. MAGNETIC RESONANCE IMAGING, 1993, 11 (01) : 3 - 6
  • [4] A METHOD OF CORONARY MR ANGIOGRAPHY
    DUMOULIN, CL
    SOUZA, SP
    DARROW, RD
    ADAMS, WJ
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (04) : 705 - 710
  • [5] CORONARY-ARTERIES - BREATH-HOLD MR ANGIOGRAPHY
    EDELMAN, RR
    MANNING, WJ
    BURSTEIN, D
    PAULIN, S
    [J]. RADIOLOGY, 1991, 181 (03) : 641 - 643
  • [6] HINKS R S, 1988, Magnetic Resonance Imaging, V6, P48
  • [7] HOFMAN MBM, 1995, COMPUT ASSIST TOMOGR, V19, P56
  • [8] CORONARY-ARTERIES - 3-DIMENSIONAL MR-IMAGING WITH FAT SATURATION AND MAGNETIZATION TRANSFER CONTRAST
    LI, D
    PASCHAL, CB
    HAACKE, EM
    ADLER, LP
    [J]. RADIOLOGY, 1993, 187 (02) : 401 - 406
  • [9] FAT-SUPPRESSED BREATH-HOLD MAGNETIC-RESONANCE CORONARY ANGIOGRAPHY
    MANNING, WJ
    LI, W
    BOYLE, NG
    EDELMAN, RR
    [J]. CIRCULATION, 1993, 87 (01) : 94 - 104
  • [10] FAST SPIRAL CORONARY-ARTERY IMAGING
    MEYER, CH
    HU, BS
    NISHIMURA, DG
    MACOVSKI, A
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (02) : 202 - 213