DETERMINATION OF ENVIRONMENTAL CONTAMINANTS USING AN ELECTROSPRAY INTERFACE COMBINED WITH AN ION TRAP MASS-SPECTROMETER

被引:54
作者
LIN, HY [1 ]
VOYKSNER, RD [1 ]
机构
[1] RES TRIANGLE INST,POB 12194,RES TRIANGLE PK,NC 27709
关键词
D O I
10.1021/ac00052a023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A commercial electrospray source was interfaced with an ion trap mass spectrometer (ITMS) to analyze compounds of environmental concern. The system was optimized to achieve maximum sensitivity. Ions were injected into the trap, which was held st a helium pressure of 3 X 10(-4) Torr, at a q(z) value of 0.1-0.15. Collisional activation of ions generated from pesticides and dyes was achieved in the electrospray transport region by adjusting the repeller voltage. The ion trap was also used to provide structural information about the [M + H]+ ions formed. Collision-induced decomposition spectra from both processes were similar. Collisional activation in the electrospray transport region required high sample purity. The MS/MS spectra generated in the ITMS were less susceptible to interference from matrix components; however, the acquisition of the MS/MS spectra required extensive instrument setup. Liquid chromatography/electrospray-ITMS was used to analyze a spiked water sample directly. Full-scan electrospray CID spectra were obtained on 10-30-pg quantities of material, resulting in low ppb detection,
引用
收藏
页码:451 / 456
页数:6
相关论文
共 27 条
[1]   DESIGN AND PERFORMANCE OF A NOVEL ELECTROSPRAY INTERFACE [J].
ALLEN, MH ;
VESTAL, ML .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (01) :18-26
[2]   LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY OF POLAR COMPOUNDS OF ENVIRONMENTAL INTEREST [J].
BEHYMER, TD ;
BELLAR, TA ;
BUDDE, WL .
ANALYTICAL CHEMISTRY, 1990, 62 (15) :1686-1690
[3]   THE MATRIX EFFECT IN PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY AND RELIABLE QUANTIFICATION BY ISOTOPE-DILUTION [J].
BROWN, FR ;
DRAPER, WM .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (09) :515-521
[4]   DETERMINATION OF ETHYLENETHIOUREA IN CROPS USING PARTICLE BEAM LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
DOERGE, DR ;
MILES, CJ .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :1999-2001
[5]   ELECTROSPRAY IONIZATION-PRINCIPLES AND PRACTICE [J].
FENN, JB ;
MANN, M ;
MENG, CK ;
WONG, SF ;
WHITEHOUSE, CM .
MASS SPECTROMETRY REVIEWS, 1990, 9 (01) :37-70
[6]   TANDEM-IN-SPACE AND TANDEM-IN-TIME MASS-SPECTROMETRY - TRIPLE QUADRUPOLES AND QUADRUPOLE ION TRAPS [J].
JOHNSON, JV ;
YOST, RA ;
KELLEY, PE ;
BRADFORD, DC .
ANALYTICAL CHEMISTRY, 1990, 62 (20) :2162-2172
[7]  
KAISER RE, 1990, RAPID COMMUN MASS SP, V4, P30
[8]   USE OF A SINGLE-QUADRUPOLE MASS-SPECTROMETER FOR COLLISION-INDUCED DISSOCIATION STUDIES OF MULTIPLY CHARGED PEPTIDE IONS PRODUCED BY ELECTROSPRAY IONIZATION [J].
KATTA, V ;
CHOWDHURY, SK ;
CHAIT, BT .
ANALYTICAL CHEMISTRY, 1991, 63 (02) :174-178
[9]   DETERMINATION OF CHLORINATED PHENOXY ACID AND ESTER HERBICIDES IN SOIL AND WATER BY LIQUID-CHROMATOGRAPHY PARTICLE BEAM MASS-SPECTROMETRY AND ULTRAVIOLET-ABSORPTION SPECTROPHOTOMETRY [J].
KIM, IS ;
SASINOS, FI ;
STEPHENS, RD ;
WANG, J ;
BROWN, MA .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :819-823
[10]   ELECTROSPRAY - ITS POTENTIAL AND LIMITATIONS AS AN IONIZATION METHOD FOR BIOMOLECULES [J].
MANN, M .
ORGANIC MASS SPECTROMETRY, 1990, 25 (11) :575-587