STUDIES ON SYSTEM PERFORMANCE AND SENSITIVITY IN ION CHROMATOGRAPHY

被引:12
作者
JACKSON, PE [1 ]
ROMANO, JP [1 ]
WILDMAN, BJ [1 ]
机构
[1] WATERS CORP,MILFORD,MA 01757
关键词
D O I
10.1016/0021-9673(95)00131-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Improvements in HPLC instrumentation, suppressor technology and ion-exchange columns have occurred over the past several years to the point where an ion chromatograph can now be configured for anion analysis using a considerable variety of hardware, suppressor and column combinations. A number of parameters, including hardware configuration, effect of temperature, column type and suppressor device, were studied with a view toward optimizing the performance of an ion chromatographic (IC) system. It was found that dual-piston, reciprocating pumps used with few-pressure pulse dampeners significantly reduced baseline noise for both suppressed and non-suppressed conductivity detector combinations, while column temperature control proved essential in order to achieve routine sub-ppb detectability in non-suppressed IC. In general, the use of suppressed IC resulted in lower detection limits than non-suppressed IC when using the same columns and hardware. Of the columns studied, the methacrylate-based HR column was found to give the best overall separation selectivity when using a carbonate-bicarbonate eluent and suppressed conductivity detection. The majority of column and suppressor combinations evaluated gave acceptable performance, although some gave less than satisfactory results. Also, some combinations resulted in lower than expected analytical results, particularly for chloride, when quantitated using single-point calibration. In addition to the use of commercially available suppressor devices, there is also a large number of high-capacity cation exchangers which can be used as suppressors and these columns, in some instances, may offer equivalent (or superior) performance compared to the commercial devices.
引用
收藏
页码:3 / 12
页数:10
相关论文
共 13 条
[1]   SIMPLIFIED STATISTICS FOR SMALL NUMBERS OF OBSERVATIONS [J].
DEAN, RB ;
DIXON, WJ .
ANALYTICAL CHEMISTRY, 1951, 23 (04) :636-638
[2]   THEORETICAL APPROACH OF DUAL-COLUMN ION CHROMATOGRAPHY [J].
DOURYBERTHOD, M ;
GIAMPAOLI, P ;
PITSCH, H ;
SELLA, C ;
POITRENAUD, C .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2257-2263
[3]   ORIGIN OF SYSTEM PEAKS IN SINGLE-COLUMN ION CHROMATOGRAPHY OF INORGANIC ANIONS USING HIGH PH BORATE-GLUCONATE BUFFERS AND CONDUCTIVITY DETECTION [J].
ERKELENS, C ;
BILLIET, HAH ;
DEGALAN, L ;
DELEER, EWB .
JOURNAL OF CHROMATOGRAPHY, 1987, 404 (01) :67-72
[4]  
HADDAD PR, 1990, J CHROMATOGR LIBRARY, V46
[5]  
HECKENBERG AL, 1989, INNOVATIVE METHODS I
[6]   STUDIES ON ELUENTS SUITABLE FOR USE WITH SIMULTANEOUS CONDUCTIVITY AND DIRECT UV DETECTION IN NONSUPPRESSED ION CHROMATOGRAPHY [J].
JACKSON, PE ;
BOWSER, T .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :33-41
[7]   ELIMINATION OF MATRIX INTERFERENCES IN ION CHROMATOGRAPHIC ANALYSIS OF DIFFICULT AQUEOUS SAMPLES [J].
JONES, WR ;
JANDIK, P .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 1989, 27 (08) :449-455
[8]   NEW MEMBRANE-BASED ELECTROLYTIC SUPPRESSOR DEVICE FOR SUPPRESSED CONDUCTIVITY DETECTION IN ION CHROMATOGRAPHY [J].
RABIN, S ;
STILLIAN, J ;
BARRETO, V ;
FRIEDMAN, K ;
TOOFAN, M .
JOURNAL OF CHROMATOGRAPHY, 1993, 640 (1-2) :97-109
[9]  
ROBARDS K, 1994, PRINCIPLES PRACTICE, pCH9
[10]   REGULATED METHODS FOR ION ANALYSIS [J].
ROMANO, JP ;
KROL, J .
JOURNAL OF CHROMATOGRAPHY, 1992, 602 (1-2) :205-211