AN NMR PHASED-ARRAY FOR HUMAN CARDIAC P-31 SPECTROSCOPY

被引:56
作者
HARDY, CJ
BOTTOMLEY, PA
ROHLING, KW
ROEMER, PB
机构
[1] Development Center, Schenectady, New York, 12301
关键词
D O I
10.1002/mrm.1910280106
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A four‐coil phased‐array 31P NMR receiver was designed and tested for human cardiac applications, to determine whether the combination of relatively high signal‐to‐noise ratio (SNR) and large field of view produced in 1H imaging is also realized for in vivo 31P spectroscopy. Spectra were acquired in parallel from an array of four overlapping 6.5‐cm surface coils using one‐ and two‐dimensional phase‐encoding pulse sequences and were optimally combined to yield composite spectroscopic images. The phased array was found to generate useful 31P spectra from a 2.5‐fold wider lateral region around the anterior myocardium than a single receiver of the same size as the array elements, with no increase in imaging time. In addition, the sensitive depth was increased by up to 2 cm over that of a single coil. Spectra could be acquired in roughly 15 min from a region extending to the middle of the heart, with voxel sizes of 2 X 2 X 4 cm3. For the average heart voxel, the SNR of the combined spectrum was higher than that of the best spectrum from any one coil in the array by 30%, with some voxels showing an increase as high as 60%.© 1992 Academic Press,Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:54 / 64
页数:11
相关论文
共 15 条
[1]   NORMAL AND DIFFUSELY ABNORMAL MYOCARDIUM IN HUMANS - FUNCTIONAL AND METABOLIC CHARACTERIZATION WITH P-31 MR SPECTROSCOPY AND CINE MR IMAGING [J].
AUFFERMANN, W ;
CHEW, WM ;
WOLFE, CL ;
TAVARES, NJ ;
PARMLEY, WW ;
SEMELKA, RC ;
DONNELLY, T ;
CHATTERJEE, K ;
HIGGINS, CB .
RADIOLOGY, 1991, 179 (01) :253-259
[2]   MYOCARDIAL HIGH-ENERGY PHOSPHATE-METABOLISM AND ALLOGRAFT-REJECTION IN PATIENTS WITH HEART-TRANSPLANTS [J].
BOTTOMLEY, PA ;
WEISS, RG ;
HARDY, CJ ;
BAUMGARTNER, WA .
RADIOLOGY, 1991, 181 (01) :67-75
[3]   PHOSPHATE METABOLITE IMAGING AND CONCENTRATION MEASUREMENTS IN HUMAN HEART BY NUCLEAR-MAGNETIC-RESONANCE [J].
BOTTOMLEY, PA ;
HARDY, CJ ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :425-434
[4]   ALTERED MYOCARDIAL HIGH-ENERGY PHOSPHATE METABOLITES IN PATIENTS WITH DILATED CARDIOMYOPATHY [J].
HARDY, CJ ;
WEISS, RG ;
BOTTOMLEY, PA ;
GERSTENBLITH, G .
AMERICAN HEART JOURNAL, 1991, 122 (03) :795-801
[5]   SPATIAL LOCALIZATION IN 2 DIMENSIONS USING NMR DESIGNER PULSES [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03) :647-654
[6]   P-31 SPECTROSCOPIC LOCALIZATION USING PINWHEEL NMR EXCITATION PULSES [J].
HARDY, CJ ;
BOTTOMLEY, PA .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :315-327
[7]   BROAD-BAND NUCLEAR MAGNETIC-RESONANCE PULSES WITH TWO-DIMENSIONAL SPATIAL SELECTIVITY [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (04) :1513-1516
[8]   NOISE CORRELATIONS EXIST FOR INDEPENDENT RF COILS [J].
HARPEN, MD .
MAGNETIC RESONANCE IN MEDICINE, 1992, 23 (02) :394-397
[9]   NOISE CORRELATIONS IN DATA SIMULTANEOUSLY ACQUIRED FROM MULTIPLE SURFACE COIL ARRAYS [J].
HAYES, CE ;
ROEMER, PB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 16 (02) :181-191
[10]  
HESMANOWICZ A, 1991, MAGNET RESON MED, V20, P36