GC-FTIRS - APPLICATIONS IN ORGANIC TRACE ANALYSIS

被引:6
作者
MALISSA, H
KREINDL, T
WINSAUER, K
机构
[1] Institute of Chemistry, Department of Analytical Chemistry, Johannes Kepler University Linz, Linz
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 1990年 / 337卷 / 07期
关键词
D O I
10.1007/BF00322262
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The GC-FTIRS coupling used as a measuring instrument in trace analytical procedures can be fully effective only, if the maximum possible sensitivity is provided simultaneously with undistorted chromatographic and spectrometric representation of the eluted compounds. Great efforts have been made in last years to design improved interfacing and measurement principles. GC capillary separation with flow-through gas cells (lightpipes), matrix isolation and cryodeposition techniques are discussed and compared in this paper, especially in terms of sensitivity. Examples of applications on the determination of organic traces in various matrices, e.g. extracts of sediments, coal, beverages and fruits are given. It could be demonstrated that the minimum identification concentration of a herbicide in ground- and drinking water is approximately 1 ppb using an analytical procedure with solid state enrichment, large sample injection and GC-FTIRS with the light-pipe technique. © 1990 Springer-Verlag.
引用
收藏
页码:843 / 847
页数:5
相关论文
共 33 条
[1]   CRYOGENICALLY COOLED INTERFACE FOR GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY [J].
BROWN, RS ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1988, 60 (14) :1483-1488
[2]   LIGHTPIPE TEMPERATURE AND OTHER FACTORS AFFECTING SIGNAL IN GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SPECTROMETRY [J].
BROWN, RS ;
COOPER, JR ;
WILKINS, CL .
ANALYTICAL CHEMISTRY, 1985, 57 (12) :2275-2279
[3]  
FISCHBOCK G, 1988, MIKROCHIM ACTA, V1, P27
[4]   CAPILLARY GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED MICROSPECTROMETRY AT SUBAMBIENT TEMPERATURE [J].
FUOCO, R ;
SHAFER, KH ;
GRIFFITHS, PR .
ANALYTICAL CHEMISTRY, 1986, 58 (14) :3249-3254
[5]   EFFECTS OF LIGHTPIPE DIMENSIONS ON GAS-CHROMATOGRAPHY FOURIER-TRANSFORM INFRARED SENSITIVITY [J].
GISS, GN ;
WILKINS, CL .
APPLIED SPECTROSCOPY, 1984, 38 (01) :17-20
[6]  
Griffith P.R., 1986, FOURIER TRANSFORM IN
[7]   OPTIMIZED SAMPLING IN GAS CHROMATOGRAPHY INFRARED SPECTROSCOPY INTERFACE [J].
GRIFFITHS, PR .
APPLIED SPECTROSCOPY, 1977, 31 (04) :284-288
[8]  
GRIFFITHS PR, 1983, ANAL CHEM, V55, P1361, DOI 10.1021/ac00263a784
[9]  
GRIFFITHS PR, 1987, MIKROCHIM ACTA, V3, P47
[10]   THE HYPHENATION OF CHROMATOGRAPHY AND FT-IR SPECTROMETRY [J].
GRIFFITHS, PR ;
PENTONEY, SL ;
GIORGETTI, A ;
SHAFER, KH .
ANALYTICAL CHEMISTRY, 1986, 58 (13) :1349-&