RADIOTHERAPEUTIC COMPUTED-TOMOGRAPHY WITH SCANNED PHOTON BEAMS

被引:41
作者
BRAHME, A
LIND, B
NAFSTADIUS, P
机构
[1] KAROLINSKA INST, DEPT RADIAT PHYS, POB 60204, S-10401 STOCKHOLM 60, SWEDEN
[2] UNIV STOCKHOLM, S-10401 STOCKHOLM, SWEDEN
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1987年 / 13卷 / 01期
关键词
D O I
10.1016/0360-3016(87)90265-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Radiotherapeutic computed tomography is a powerful technique to generate anatomical transversal tomograms of the patient in treatment position by using the therapy beam from the treatment unit. For this purpose the treatment unit has to be equipped with a detector array that can detect the beam transmitted through the patient and a computer that analyzes the data and performs the back projection. When the treatment unit uses scanned elementary photon beams, the only practical technique available for generating high quality high energy photon beams, the operation principle and, to some extent, the image quality is similar to that of a 3rd generation CT-scanner. The optimum choice of detection geometry and type of radiation detectors for radiotherapeutic computed tomography particularly at high photon energies are discussed indicating the merits of BGO (bismuthgermanate) or CWO (cadmiumtungstate) photo diod arrays. The first tomographic images of a thorax phantom at an acceleration potential of 50 MV using such detectors are presented. The image contrast is similar to that for 300 kV X rays mainly because the considerable influence of pair production at 50 MV. Line spread and modulation transfer functions are presented indicating a resolution of the order of two millimeters using a crystal thickness of 5 mm. The advantages with radiotherapeutic computed tomography, beside forming a new general communication channel between different diagnostic techniques, dose planning, and radiation delivery, are the elimination of position errors and the provision of exact attenuation data for dose planning.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 13 条
[1]  
Biggs P J, 1979, Med Phys, V6, P291, DOI 10.1118/1.594580
[2]   ELECTRON AND PHOTON BEAMS FROM A 50 MEV RACETRACK MICROTRON [J].
BRAHME, A ;
KRAEPELIEN, T ;
SVENSSON, H .
ACTA RADIOLOGICA ONCOLOGY, 1980, 19 (04) :305-319
[3]   DOSIMETRY AND QUALITY SPECIFICATION OF HIGH-ENERGY PHOTON BEAMS [J].
BRAHME, A ;
ANDREO, P .
ACTA RADIOLOGICA ONCOLOGY, 1986, 25 (03) :213-223
[4]  
BRAHME A, 1986, IN PRESS INT J RAD O
[5]  
BRAHME A, 1980, IEEE T NS, V28, P1880
[6]  
BRAHME A, 1979, 12 COMB M P C MED BI
[7]   DOSIMETRIC EVALUATION OF A PENCIL-BEAM ALGORITHM FOR ELECTRONS EMPLOYING A TWO-DIMENSIONAL HETEROGENEITY CORRECTION [J].
HOGSTROM, KR ;
MILLS, MD ;
MEYER, JA ;
PALTA, JR ;
MELLENBERG, DE ;
MEOZ, RT ;
FIELDS, RS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1984, 10 (04) :561-569
[8]   ELECTRON-BEAM DOSE PLANNING USING GAUSSIAN BEAMS - ENERGY AND SPATIAL SCALING WITH INHOMOGENEITIES [J].
LAX, I ;
BRAHME, A .
ACTA RADIOLOGICA ONCOLOGY, 1985, 24 (01) :75-85
[9]  
LIND B, 1985, 7 P ICMP MED BIOL S, V23, P953
[10]   COMPUTER-ASSISTED DOSIMETRY OF SCANNED ELECTRON AND PHOTON BEAMS FOR RADIATION-THERAPY [J].
NAFSTADIUS, P ;
BRAHME, A ;
NORDELL, B .
RADIOTHERAPY AND ONCOLOGY, 1984, 2 (03) :261-269