PRECISION, ACCURACY, AND DATA ACCEPTANCE CRITERIA IN BIOPHARMACEUTICAL ANALYSIS

被引:136
作者
KARNES, HT
MARCH, C
机构
[1] Department of Pharmacy and Pharmaceutics, Virginia Commonwealth University, Richmond, Virginia, 23298-0533
关键词
VALIDATION; PRECISION; ACCURACY; QUALITY CONTROL;
D O I
10.1023/A:1018958805795
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Accuracy and precision are the most important criteria in the assessment of an analytical method, and monitoring quality control during sample analysis is essential to ensure the validity of reported results. Various approaches to testing accuracy, precision, and quality control were applied to 10 analytes from seven chromatographic bioanalytical methods. These methods include fixed interval bias and significance testing for accuracy; fixed interval percentage relative standard deviation (%RSD) and analysis of variance (ANOVA) approaches for precision; +/-20% fixed range, 99% confidence interval, multiple rules. and range chart for individuals approaches for quality control acceptance criteria. Quality control approaches were also applied to the entire run and to a bracketed approach whereby results are considered valid only if bracketed by acceptable quality control. Accuracy and precision were assessed for six runs of each analyte at three concentrations established to represent the calibration range of the analytical method. Quality control acceptance criteria were evaluated using all data sets from each of the analytical methods collected during the course of running various numbers of real samples. The data suggest that the fixed interval bias criteria for accuracy was a more liberal method of accuracy assessment because three of the seven methods would have been rejected according to the significance testing criteria whereas all were acceptable by the fixed internal bias criteria. Precision can be effectively assessed for between- and within-run data by criteria set on unconfounded %RSD values or by separation of the sources of variation using an ANOVA approach applied to confounded data. The percentage of samples rejected for the 99% confidence interval applied to brackets, the multiple rules approach applied to the entire run, and the individual range chart approach applied to brackets were comparable and were found to be 7.0, 6.2 and 8.3 percent respectively. The +/-20% fixed range criteria applied to the two-thirds of the run resulted in just 2.9% sample rejection and was not considered comparable to the other methods.
引用
收藏
页码:1420 / 1426
页数:7
相关论文
共 11 条
[1]   EVALUATION OF CRITERIA FOR THE ACCEPTANCE OF BIOANALYTICAL DATA [J].
CAUSEY, AG ;
HILL, HM ;
PHILLIPS, LJ .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) :625-628
[2]   CALIBRATION AND VALIDATION OF LINEARITY IN CHROMATOGRAPHIC BIOPHARMACEUTICAL ANALYSIS [J].
KARNES, HT ;
MARCH, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (10-12) :911-918
[3]   VALIDATION OF BIOANALYTICAL METHODS [J].
KARNES, HT ;
SHIU, G ;
SHAH, VP .
PHARMACEUTICAL RESEARCH, 1991, 8 (04) :421-426
[4]   A COMPREHENSIVE METHOD VALIDATION STRATEGY FOR BIOANALYTICAL APPLICATIONS IN THE PHARMACEUTICAL-INDUSTRY .2. STATISTICAL-ANALYSES [J].
LANG, JR ;
BOLTON, S .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1991, 9 (06) :435-442
[5]  
PARVIN CA, 1992, CLIN CHEM, V38, P364
[6]  
PARVIN CA, 1992, CLIN CHEM, V38, P358
[7]   ANALYTICAL METHODS VALIDATION - BIOAVAILABILITY, BIOEQUIVALENCE AND PHARMACOKINETIC STUDIES [J].
SHAH, VP ;
MIDHA, KK ;
DIGHE, S ;
MCGILVERAY, IJ ;
SKELLY, JP ;
YACOBI, A ;
LAYLOFF, T ;
VISWANATHAN, CT ;
COOK, CE ;
MCDOWALL, RD ;
PITTMAN, KA ;
SPECTOR, S ;
ALBERT, KS ;
BOLTON, S ;
COOK, CE ;
DIGHE, S ;
DOBRINSKA, M ;
DOUB, W ;
EICHELBAUM, M ;
FINDLAY, JWA ;
GALLICANO, K ;
GARLAND, W ;
HARDY, DJ ;
HULSE, JD ;
KARNES, HT ;
MCDOWALL, RD ;
LANGE, R ;
LAYLOFF, T ;
MASON, WD ;
MCKAY, G ;
MCGILVERAY, IJ ;
MIDHA, KK ;
ORMSBY, E ;
OVERPECK, J ;
PITTMAN, KA ;
PLATTENBERG, HD ;
SHAH, VP ;
SHIU, G ;
SITAR, D ;
SKELLY, JP ;
SORGEL, F ;
SPECTOR, S ;
STEWART, JT ;
VISWANATHAN, CT ;
YACOBI, A ;
YUH, L .
PHARMACEUTICAL RESEARCH, 1992, 9 (04) :588-592
[8]   A PREDICTIVE VALUE MODEL FOR QUALITY-CONTROL - EFFECTS OF THE PREVALENCE OF ERRORS ON THE PERFORMANCE OF CONTROL PROCEDURES [J].
WESTGARD, JO ;
GROTH, T .
AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1983, 80 (01) :49-56
[9]  
WESTGARD JO, 1981, CLIN CHEM, V27, P493
[10]  
WESTGARD JO, 1984, SCAND J CLIN LAB INV, V44, P19