TANDEM MASS-SPECTROMETRY OF PEPTIDES USING HYBRID AND 4-SECTOR INSTRUMENTS - A COMPARATIVE-STUDY

被引:88
作者
BEAN, MF
CARR, SA
THORNE, GC
REILLY, MH
GASKELL, SJ
机构
[1] SMITHKLINE BEECHAM PHARMACEUT,POB 1539,KING OF PRUSSIA,PA 19406
[2] BAYLOR UNIV,CTR EXPTL THERAPEUT,HOUSTON,TX 77030
关键词
D O I
10.1021/ac00014a024
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Product-ion spectra produced by high- and low-energy collisionally activated dissociation (CAD) of [M + H]+ ions of a series of peptides (M(r) 550-2500) have been compared on four-sector and hybrid tandem mass spectrometers, respectively. The fast atom bombardment product-ion spectra obtained for the smallest peptide analyzed (methionine-enkephalln) were remarkably similar, but substantial differences in fragmentation were observed for the heavier analytes. For peptides with M(r) > 1000, more complete sequence information was obtained from high-energy CAD on the four-sector instrument. Nevertheless, low-energy CAD on the hybrid mass spectrometer was able to produce partial sequence information even for the largest of the peptides compared. Limits of analysis, defined as the least quantities of analyte for which product-ion spectra of essentially uncompromised quality could be obtained, were similar (ca. 15 pmol) for small peptides, but lower limits were achieved for larger peptides (M(r) > 1000) with the four-sector instrument. High-energy CAD spectra were found to be highly reproducible, with qualitatively similar spectra obtained over a wide range of operating conditions. In contrast, it was necessary to carefully control collision gas pressures and collision energies in order to obtain good reproducible data for low-energy CAD. Experimental procedures for obtaining reproducible spectra with good sensitivity for peptides on the hybrid instrument are presented.
引用
收藏
页码:1473 / 1481
页数:9
相关论文
共 84 条
  • [1] COLLISION-INDUCED DISSOCIATION OF PEPTIDE IONS .3. COMPARISON OF RESULTS OBTAINED USING SECTOR-QUADRUPOLE HYBRIDS WITH THOSE FROM TANDEM DOUBLE-FOCUSING INSTRUMENTS
    ALEXANDER, AJ
    THIBAULT, P
    BOYD, RK
    CURTIS, JM
    RINEHART, KL
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 98 (02): : 107 - 134
  • [2] EXPERIMENTAL INVESTIGATIONS OF FACTORS CONTROLLING THE COLLISION-INDUCED DISSOCIATION SPECTRA OF PEPTIDE IONS IN A TANDEM HYBRID MASS-SPECTROMETER .1. LEUCINE ENKEPHALIN
    ALEXANDER, AJ
    BOYD, RK
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1989, 90 (03): : 211 - 240
  • [3] Alexander AJ, 1989, RAPID COMMUN MASS SP, V3, P364
  • [4] ALEXANDER AJ, 1989, RAPID COMMUN MASS SP, V3, P30
  • [5] ANDEREGG RJ, 1988, J BIOL CHEM, V263, P18236
  • [6] CORRECTION OF THE CDNA-DERIVED PROTEIN-SEQUENCE OF PROSTATIC SPERMINE BINDING-PROTEIN - PIVOTAL ROLE OF TANDEM MASS-SPECTROMETRY IN SEQUENCE-ANALYSIS
    ANDEREGG, RJ
    CARR, SA
    HUANG, IY
    HIIPAKKA, RA
    CHANG, C
    LIAO, S
    [J]. BIOCHEMISTRY, 1988, 27 (12) : 4214 - 4221
  • [7] ASCHCROFT AE, 1988, 36TH P ASMS C MASS S, P1156
  • [8] TANDEM MASS-SPECTROMETRY OF LEUCINE ENKEPHALIN AND PHYSALAEMIN USING A HYBRID INSTRUMENT
    BAETEN, W
    CLAEREBOUDT, J
    VANDENHEUVEL, H
    CLAEYS, M
    [J]. BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (09): : 727 - 732
  • [9] Barber M, 1987, Rapid Commun Mass Spectrom, V1, P80, DOI 10.1002/rcm.1290010505
  • [10] BATEMAN RH, 1982, 30TH ANN C MASS SPEC, P516