THIN-FILM POLYAMINE BIOSENSOR - SUBSTRATE-SPECIFICITY AND APPLICATION TO FISH FRESHNESS DETERMINATION

被引:38
作者
CHEMNITIUS, GC
SUZUKI, M
ISOBE, K
KIMURA, J
KARUBE, I
SCHMID, RD
机构
[1] NEC CORP LTD,MIYAMAE KU,KAWASAKI,KANAGAWA 213,JAPAN
[2] UNIV TOKYO,ADV SCI & TECHNOL RES CTR,MEGURO KU,TOKYO 153,JAPAN
关键词
AMPEROMETRY; FLOW SYSTEM; BIOSENSORS; ENZYME ELECTRODES; FISH; POLYAMINES; PUTRESCINE;
D O I
10.1016/0003-2670(92)85430-E
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyamine biosensor was developed by immobilizing putrescine oxidase on micro planar thin-film hydrogen peroxide electrodes. The sensor showed a rapid response to putrescine (90% response: 40 s) and the relationship between putrescine concentration and output current was linear between 0.03 and 3-mu-M under the optimum reaction conditions (pH 8.0, 30-degrees-C). The substrate specificity of the polyamine sensor was determined using a flow-injection analysis system. In addition to the main substrate putrescine, the sensor also converted cadaverine (46%), spermidine (45%), agmatine (13%), 1,6-diaminohexane (3%), 1,7-diaminoheptane (2%) and tyramine (13%, non-enzymatic response). These conversion rates were high compared with those of soluble putrescine oxidase. This is probably due to broadening of the enzyme's active centre during the immobilization procedure. The sensor was applied to fish freshness determination during a fish storage experiment. The sensor response obtained in fish extracts increased with increasing storage time and agreed with liquid chromatographic amine determinations.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 21 条
[1]  
Askar A, 1986, BIOGENE AMINE LEBENS
[2]   MINIATURIZED DISPOSABLE BIOSENSORS [J].
BILITEWSKI, U ;
CHEMNITIUS, GC ;
RUGER, P ;
SCHMID, RD .
SENSORS AND ACTUATORS B-CHEMICAL, 1992, 7 (1-3) :351-355
[3]  
DAWSON RMC, 1986, DATA BIOCH RES, P438
[4]  
FLOSSDORF J, 1987, Patent No. 37376047
[5]   AMINO OXIDASE AMPEROMETRIC BIOSENSOR FOR POLYAMINES [J].
GASPARINI, R ;
SCARPA, M ;
DIPAOLO, ML ;
STEVANATO, R ;
RIGO, A .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1991, 25 (02) :307-315
[6]  
HUI JY, 1983, J ASSOC OFF ANA CHEM, V66, P853
[7]  
KIEHNE A, 1991, ABSCHLUSSARBEIT DEP
[8]   A SPECIFIC ENZYME ELECTRODE FOR SPERMINE AND SPERMIDINE [J].
MACHOLAN, L ;
JILKOVA, D .
COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 1983, 48 (02) :672-678
[9]   A MICRO PLANAR AMPEROMETRIC GLUCOSE SENSOR USING AN ISFET AS A REFERENCE ELECTRODE [J].
MURAKAMI, T ;
NAKAMOTO, S ;
KIMURA, J ;
KURIYAMA, T ;
KARUBE, I .
ANALYTICAL LETTERS, 1986, 19 (19-20) :1973-1986
[10]  
OKADA M, 1979, J BIOCHEM-TOKYO, V86, P97