APPLICATION OF THE K(0) STANDARDIZATION METHOD IN NEUTRON-ACTIVATION ANALYSIS OF CERAMIC MATERIALS

被引:7
作者
DARDENNE, C [1 ]
DESCHAMPS, N [1 ]
REVEL, G [1 ]
RIGLET, G [1 ]
HERVIOU, C [1 ]
机构
[1] RHONE POULENC RECH, AUBERVILLIERS, FRANCE
来源
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES | 1993年 / 168卷 / 02期
关键词
D O I
10.1007/BF02040522
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical procedure has been developed for neutron activation analysis of ceramic powders, it is mainly based on the application of the K0 standardization method and on the use of pelletizing for sample preparation. Precision and accuracy have been checked through the analysis of international standards. The procedure was applied to a commercial silicon carbide sample for the determination of 42 elements. Results were interpreted in terms of repeatability and accuracy by comparison to other trace analysis techniques. Additional short half-life elements were also determined by the K0 method.
引用
收藏
页码:417 / 427
页数:11
相关论文
共 8 条
[1]  
BINNIE WP, 1988, CERAM T 1, V1, P313
[2]  
De Corte F, 1987, THESIS U GENT BELGIU
[3]  
DECORTE F, 1986, COMPILATION KO AU FA
[4]  
ERDTMANN G, 1987, 2ND INT WORKSH ACT A
[5]  
FEDOROFF M, 1971, NUCL INSTRUM METHODS, V91, P173, DOI 10.1016/0029-554X(71)90653-7
[6]  
PICCOT D, 1987, SEA767 RAPP TECHN
[7]   KO-MEASUREMENTS AND RELATED NUCLEAR-DATA COMPILATION FOR (N,GAMMA) REACTOR NEUTRON-ACTIVATION ANALYSIS .1. [J].
SIMONITS, A ;
MOENS, L ;
DECORTE, F ;
DEWISPELAERE, A ;
ELEK, A ;
HOSTE, J .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1980, 60 (02) :461-516
[8]   ZIRCONIUM AS A MULTI-ISOTOPIC FLUX RATIO MONITOR AND A SINGLE COMPARATOR IN REACTOR-NEUTRON ACTIVATION-ANALYSIS [J].
SIMONITS, A ;
DECORTE, F ;
HOSTE, J .
JOURNAL OF RADIOANALYTICAL CHEMISTRY, 1976, 31 (02) :467-486