TRANSMISSION ELECTRON-MICROSCOPIC AND HIGH-VOLTAGE ELECTRON-MICROSCOPIC OBSERVATIONS OF THE BONE AND OSTEOCYTE ACTIVITY ADJACENT TO UNLOADED DENTAL IMPLANTS PLACED IN DOGS

被引:36
作者
STEFLIK, DE
HANES, PJ
SISK, AL
PARR, GR
SONG, MJ
LAKE, FT
MCKINNEY, RV
机构
[1] WADSWORTH CTR LABS & RES, HVEM FACIL, ALBANY, NY USA
[2] MED COLL GEORGIA, SCH DENT, DEPT ORAL BIOL, AUGUSTA, GA 30912 USA
[3] MED COLL GEORGIA, SCH DENT, DEPT PROSTHODONT, AUGUSTA, GA 30912 USA
[4] MED COLL GEORGIA, SCH DENT, DEPT PERIODONTOL, AUGUSTA, GA 30912 USA
[5] MED COLL GEORGIA, SCH DENT, DEPT ORAL & MAXILLOFACIAL SURG, AUGUSTA, GA 30912 USA
关键词
DENTAL IMPLANTATION; ENDOSSEOUS; DENTAL IMPLANTS; BONE AND BONES; COLLAGEN; OSTEOCYTES; MICROSCOPY; ELECTRON;
D O I
10.1902/jop.1992.63.5.443
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
THE PURPOSE OF THIS REPORT is to describe ultrastructural observations of the bone and associated tissues supporting 24 unloaded endosteal dental implants placed in mongrel dogs (canis familiaris). The following 3 specific areas of the supporting tissues were targeted: 1) the osteocyte populations; 2) the mineralized collagen fiber matrix of the bone; and 3) an electron dense interfacial deposit. To investigate these areas, transmission electron microscopy and high voltage electron microscopic (HVEM) protocols were emphasized. HVEM permitted stereologic observations. Further, all observations were obtained from undecalcified tissues obtained from animals with commercially available implants placed into the mandible. From the study we observed a mineralization pattern of the implant supporting bone that was similar to those events occurring naturally within the mandibular bone. Osteocyte morphology was similar whether the osteocytes were found well below the implant interface or close to the interface. Osteocytes within lacunae were routinely found close to the implant interface, often extending cellular processes through canaliculi to the bone-implant interface. At the interface, an electron dense deposit approximately 50 nm in thickness was often observed. In interfacial regions, densely mineralized collagen fibers were observed running primarily parallel to the implant surface. This dense mineralized tissue was separated from the interface by a mineralized, but finely fibrillar matrix of approximately 200 nm in thickness.
引用
收藏
页码:443 / 452
页数:10
相关论文
共 19 条
[1]   A 15-YEAR STUDY OF OSSEOINTEGRATED IMPLANTS IN THE TREATMENT OF THE EDENTULOUS JAW [J].
ADELL, R ;
LEKHOLM, U ;
ROCKLER, B ;
BRANEMARK, PI .
INTERNATIONAL JOURNAL OF ORAL SURGERY, 1981, 10 (06) :387-416
[2]  
AERICKSSON AR, 1983, J PROSTHET DENT, V50, P101
[3]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[4]  
DAVIES JE, 1991, CELL MATER, V1, P3
[5]   HISTOLOGICAL AND ULTRASTRUCTURAL APPEARANCE OF THE HYDROXYAPATITE BONE INTERFACE [J].
DELANGE, GL ;
DEPUTTER, C ;
DEWIJS, FLJA .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1990, 24 (07) :829-845
[6]   A HISTOLOGICAL ASSESSMENT OF THE INITIAL HEALING RESPONSE ADJACENT TO POROUS-SURFACED, TITANIUM-ALLOY DENTAL IMPLANTS IN DOGS [J].
DEPORTER, DA ;
WATSON, PA ;
PILLIAR, RM ;
MELCHER, AH ;
WINSLOW, J ;
HOWLEY, TP ;
HANSEL, P ;
MANIATOPOULOS, C ;
RODRIGUEZ, A ;
ABDULLA, D ;
PARISIEN, K ;
SMITH, DC .
JOURNAL OF DENTAL RESEARCH, 1986, 65 (08) :1064-1070
[7]  
HIPP JA, 1987, J DENT RES, V66, P186
[8]  
HOLTROP ME, 1990, BONE OSTEOBLAST OSTE, V1, P1
[9]  
LINDER L, 1983, ACTA ORTHOP SCAND, V54, P45, DOI 10.3109/17453678308992868
[10]   EVIDENCE FOR A JUNCTIONAL EPITHELIAL ATTACHMENT TO CERAMIC DENTAL IMPLANTS - A TRANSMISSION ELECTRON-MICROSCOPIC STUDY [J].
MCKINNEY, RV ;
STEFLIK, DE ;
KOTH, DL .
JOURNAL OF PERIODONTOLOGY, 1985, 56 (10) :579-591