COMPUTER-ASSISTED GENERATION OF MULTI-LEAF COLLIMATOR SETTINGS FOR CONFORMATION THERAPY

被引:25
作者
HOUNSELL, AR
SHARROCK, PJ
MOORE, CJ
SHAW, AJ
WILKINSON, JM
WILLIAMS, PC
机构
[1] N.Western Medical Physics Depa, Christie Hospital, Withington
关键词
MULTI-LEAF COLLIMATOR; CONFORMATION THERAPY; COMPUTER METHODS;
D O I
10.1259/0007-1285-65-772-321
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Techniques for the automatic set up of the individual leaf positions of a Philips multi-leaf collimator system to cover a defined target volume are described. Tumour outline data for multi-field treatments may be obtained from one of two techniques, either from simulator images or from cross-sectional computed tomography (CT) slices. In the first technique, simulator images are digitized directly from image intensifier video signals or from conventional film radiographs using a CCD camera. Corrections for image distortion are carried out before reformatting the digitized images to a common data structure. Target outlines are subsequently traced interactively on the digital image to create an outline file. In the second technique, target volumes are defined on several individual CT slices and these are then used to obtain projected graphical views from any desired angle. In both techniques, a scaled graphical representation of leaf positions is then displayed and set relative to the outer edge of the target outline. Both techniques allow interactive repositioning of single leaves when required, or the operator can specify a margin around the projected target volume. Leaf prescription data files are created and are transferred via a Decnet-OSI-Opennet network link to an Intel microcomputer, which is used to drive the device itself. Examples of both techniques are given.
引用
收藏
页码:321 / 326
页数:6
相关论文
共 10 条
[1]   CONFORMATION THERAPY AT THE ROYAL FREE HOSPITAL - A PROGRESS REPORT ON THE TRACKING COBALT PROJECT [J].
BRACE, JA ;
DAVY, TJ ;
SKEGGS, DBL ;
WILLIAMS, HS .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (648) :1068-1074
[2]   DOSE OPTIMIZATION WITH COMPUTER-CONTROLLED GANTRY ROTATION, COLLIMATOR MOTION AND DOSE-RATE VARIATION [J].
CHIN, LM ;
KIJEWSKI, PK ;
SVENSSON, GK ;
BJARNGARD, BE .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1983, 9 (05) :723-729
[3]   TISSUE STANDARD RATIOS FOR IRREGULARLY SHAPED RADIOTHERAPY FIELDS [J].
HOUNSELL, AR ;
WILKINSON, JM .
BRITISH JOURNAL OF RADIOLOGY, 1990, 63 (752) :629-634
[4]  
JORDAN TJ, 1991, PHYS MED BIOL, V36, P669
[5]  
MOORE CJ, 1988, THESIS U MANCHESTER, pCH4
[6]  
SHAW AJ, 1991, BRIT J HEALTHCARE CO, P30
[7]   BENEFITS EXPECTED FROM SIMPLE CONFORMAL RADIOTHERAPY IN THE TREATMENT OF PELVIC TUMORS [J].
TAIT, D ;
NAHUM, A ;
SOUTHALL, C ;
CHOW, M ;
YARNOLD, JR .
RADIOTHERAPY AND ONCOLOGY, 1988, 13 (01) :23-30
[8]   CONFORMATION THERAPY - A METHOD OF IMPROVING THE TUMOR TREATMENT VOLUME RATIO [J].
TATE, T ;
BRACE, JA ;
MORGAN, H ;
SKEGGS, DBL .
CLINICAL RADIOLOGY, 1986, 37 (03) :267-271
[9]  
WILLIAMS PC, 1991, BRIT J RADIOLOGY S, V64, P82
[10]  
WILLIAMS PC, 1991, BRIT J RADIOL, V64, P83