NEAR-INFRARED SPECTROSCOPY AS AN ALTERNATIVE TO BIOLOGICAL TESTING FOR QUALITY-CONTROL OF HYALURONAN - COMPARISON OF DATA PREPROCESSING METHODS FOR CLASSIFICATION

被引:17
作者
CARLSSON, AE [1 ]
JANNE, KLR [1 ]
机构
[1] PHARMACIA AB,ANALYT CHEM,S-75182 UPPSALA,SWEDEN
关键词
NEAR-INFRARED SPECTROSCOPY; PATTERN RECOGNITION; CLASSIFICATION; PRINCIPAL COMPONENTS ANALYSIS; PREPROCESSING; DERIVATIVES; MULTIPLICATIVE SCATTER CORRECTION; DISCRIMINANT PARTIAL LEAST-SQUARES; POLYSACCHARIDE; BIOLOGICAL ASSAY; QUALITY CONTROL; PHARMACEUTICALS;
D O I
10.1366/0003702953964787
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An alternative method to biological testing on animals has been studied. The method is based on pattern recognition by combination of near-infrared spectroscopy and multivariate classification. The pharmaceutical product under study is based on a high-molecular-weight carbohydrate, Hyaluronan, used as a medical device for eye surgery. The effect of data preprocessing on classification performance of approved and rejected samples was evaluated by use of principal components models for each class. With the use of multiplicative scatter correction techniques, the class discrimination was enhanced 10 times in comparison to uncorrected data. From a leave-one-out procedure including a total of 29 samples, 80% of the samples were classified in agreement with the biological reference data and the remaining 20% were classified as nonmembers. With the use of partial least-squares discriminant analysis, 90% of the predicted samples were in accordance with the biological assay.
引用
收藏
页码:1037 / 1040
页数:4
相关论文
共 13 条
  • [1] ALBANO C, 1981, PATTERN RECOGNITION
  • [2] BALAZS EA, 1980, EXP EYE RES, V31, P81
  • [3] BALAZS EA, 1980, EXP EYE RES, V31, P101
  • [4] An evaluation of SIMCA. Part 2 — classification of pyrolysis mass spectra of pseudomonas and serratia bacteria by pattern recognition using the SIMCA classifier
    Dröge, J.B.M.
    Rinsma, W.J.
    Van 'T Klooster, H.A.
    Tas, A.C.
    Van Der Greef, J.
    [J]. Journal of Chemometrics, 1987, 1 (04) : 231 - 241
  • [5] DROGE J B M, 1987, Journal of Chemometrics, V1, P221, DOI 10.1002/cem.1180010404
  • [6] Evans D. G., 1993, Journal of Near Infrared Spectroscopy, V1, P33
  • [7] RAW-MATERIALS TESTING USING SOFT INDEPENDENT MODELING OF CLASS ANALOGY ANALYSIS OF NEAR-INFRARED REFLECTANCE SPECTRA
    GEMPERLINE, PJ
    WEBBER, LD
    COX, FO
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (02) : 138 - 144
  • [8] KOWALSKI B, 1993, APPL SPECTROSC, V47, P702
  • [9] MARTENS H, 1985, APPL SPECTROSC, V39, P491
  • [10] PUTZIG CL, 1994, ANAL CHEM, V66, P26