SELECTIVE FLOW-INJECTION DETERMINATION OF METHANOL USING IMMOBILIZED ENZYME REACTORS

被引:14
作者
DEMARIA, CG
MANZANO, T
DUARTE, R
ALONSO, A
机构
[1] Departamento de Química Analítica, Nutricón y Bromatología, Faculty of Chemistry, University of Salamanca, E-37008 Salamanca, Plaza de la Merced s / n
关键词
FLUOROMETRY; FLOW INJECTION; ENZYMATIC METHODS; METHANOL;
D O I
10.1016/0003-2670(95)00040-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection procedure is described for the determination of methanol based on its alcohol oxidase-catalysed conversion to formaldehyde, which is then oxidized to formic acid by NAD(+) in the presence of formaldehyde dehydrogenase. The concentration of NADH produced is measured by fluorimetry. Both enzymes and catalase, which is added to improve enzyme stability and the extent of the overall enzymatic reaction, are immobilized or coimmobilized on controlled-pore glass. Concentrations of methanol greater than or equal to 1.2 X 10(-6) M can be analysed. The proposed procedure has a linear application range of 4.0 X 10(-6)-8.0 X 10(-5) M (fluorescence = -3.81 +/- 1.67 x 10(6) [methanol]; r = 0.998, n = 6), an R.S.D. of 1.8% at 2.4 X 10(-5) M methanol, and a sampling frequency of 30 h(-1). Enzyme reactors keep their catalytic properties for 3-4 months and can be reused for 400 determinations on average.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 24 条
[1]   AN ENZYME ELECTRODE FOR ONLINE DETERMINATION OF ETHANOL AND METHANOL [J].
BELGHITH, H ;
ROMETTE, JL ;
THOMAS, D .
BIOTECHNOLOGY AND BIOENGINEERING, 1987, 30 (09) :1001-1005
[2]  
DEMARIA CG, 1992, 1 C HISP BIOT SANT C
[3]  
DIXON M, 1979, ENZYMES, pCH7
[4]   ENZYMATIC DETERMINATION OF ALCOHOL MIXTURES AT THE NANOGRAM LEVEL BY THE STOPPED-FLOW TECHNIQUE [J].
FORSTER, E ;
SILVA, M ;
OTTO, M ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1993, 274 (01) :109-116
[5]  
FRANZBLAU A, 1992, AM IND HYG ASSOC J, V53, P221, DOI 10.1202/0002-8894(1992)053<0221:TUOATF>2.0.CO
[6]  
2
[7]  
GILES HG, 1993, CLIN CHEM, V39, P693
[8]  
GNEKOW B, 1976, AM J ENOL VITICULT, V27, P1
[9]   AMPEROMETRIC BIOSENSORS BASED ON AN APPARENT DIRECT ELECTRON-TRANSFER BETWEEN ELECTRODES AND IMMOBILIZED PEROXIDASES - PLENARY LECTURE [J].
GORTON, L ;
JONSSONPETTERSSON, G ;
CSOREGI, E ;
JOHANSSON, K ;
DOMINGUEZ, E ;
MARKOVARGA, G .
ANALYST, 1992, 117 (08) :1235-1241
[10]   ENZYME ELECTRODE AND THERMISTOR PROBES FOR DETERMINATION OF ALCOHOLS WITH ALCOHOL OXIDASE [J].
GUILBAULT, GG ;
DANIELSSON, B ;
MANDENIUS, CF ;
MOSBACH, K .
ANALYTICAL CHEMISTRY, 1983, 55 (09) :1582-1585