CREEP OF CONVENTIONAL AND MICROFILLED DENTAL COMPOSITES

被引:30
作者
PAPADOGIANIS, Y [1 ]
BOYER, DB [1 ]
LAKES, RS [1 ]
机构
[1] UNIV IOWA,DEPT BIOMED ENGN,IOWA CITY,IA 52242
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 1984年 / 18卷 / 01期
关键词
COMPOSITE MATERIALS - Creep;
D O I
10.1002/jbm.820180104
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The creep of microspecimens of two conventional and two microfilled composites was studied using a torsional creep apparatus. Small stresses below the materials' proportional limits were maintained for 3 hr and recovery was monitored for 30 hr. Creep curves were obtained at 21. 5, 37, and 50 degree C, and three torque levels. The composites exhibited linear viscoelastic behavior at low deformations. The magnitude of creep depended on the amount and type of resin in the composites. The materials did not recover their original shape after 30 hr after the stress was removed. No transitions were observed in the temperature range employed. The shear moduli decreased with temperature and are in reasonable agreement with literature values obtained with other tests.