SPIRAL CT ANGIOGRAPHY OF ABDOMINAL AORTIC-ANEURYSMS

被引:37
作者
COSTELLO, P [1 ]
GAA, J [1 ]
机构
[1] HARVARD UNIV,SCH MED,BOSTON,MA
关键词
ANEURYSM; AORTIC; CT; AORTA; COMPUTED TOMOGRAPHY (CT); HELICAL; TECHNOLOGY;
D O I
10.1148/radiographics.15.2.7761643
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Spiral computed tomographic (CT) angiography involves a timed intravenous injection of contrast material, rapid data acquisition, reconstruction at narrow intervals, image editing, and maximum intensity projection image processing, Spiral CT angiography of the abdominal aorta was performed in 28 patients for preoperative aneurysm assessment, The results were unsatisfactory in only two patients; 54 main and 12 accessory renal arteries and 26 aortic aneurysms were seen, In 17 of the 26 patients with aneurysms, there was surgical confirmation of the CT angiographic findings regarding size, suprarenal extension, and distal extent of the aneurysms, with no additional renal arteries detected, With this technique, the relationship of an aneurysm to renal, superior mesenteric, and inferior mesenteric arteries can be assessed, CT angiography also depicts the proximal extent of an aneurysm, which is the single most crucial piece of preoperative information; an associated renal artery stenosis or occlusion; or an accessory renal artery, CT angiography can be performed as an outpatient procedure before vascular surgery with fewer risks, with lower radiation dose, and at one-third the cost of conventional angiography.
引用
收藏
页码:397 / 406
页数:10
相关论文
共 10 条
  • [1] BRINK JA, 1992, RADIOLOGY, V185, P126
  • [2] SPIRAL VOLUMETRIC CT WITH SINGLE-BREATH-HOLD TECHNIQUE, CONTINUOUS TRANSPORT, AND CONTINUOUS SCANNER ROTATION
    KALENDER, WA
    SEISSLER, W
    KLOTZ, E
    VOCK, P
    [J]. RADIOLOGY, 1990, 176 (01) : 181 - 183
  • [3] PREOPERATIVE EVALUATION OF ABDOMINAL AORTIC-ANEURYSM BY MR IMAGING WITH AORTOGRAPHY CORRELATION
    KOSLIN, DB
    KENNEY, PJ
    KELLER, FS
    KOEHLER, RE
    GROSS, GM
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (06) : 329 - 335
  • [4] CT ANGIOGRAPHY WITH SPIRAL CT AND MAXIMUM INTENSITY PROJECTION
    NAPEL, S
    MARKS, MP
    RUBIN, GD
    DAKE, MD
    MCDONNELL, CH
    SONG, SM
    ENZMANN, DR
    JEFFREY, RB
    [J]. RADIOLOGY, 1992, 185 (02) : 607 - 610
  • [5] ABDOMINAL AORTIC-ANEURYSM EVALUATION - COMPARISON OF US, CT, MRI, AND ANGIOGRAPHY
    PAVONE, P
    DICESARE, E
    DIRENZI, P
    MARSILI, L
    VENTURA, M
    SPARTERA, C
    PASSARIELLO, R
    [J]. MAGNETIC RESONANCE IMAGING, 1990, 8 (03) : 199 - 204
  • [6] EVALUATION OF SECTION SENSITIVITY PROFILES AND IMAGE NOISE IN SPIRAL CT
    POLACIN, A
    KALENDER, WA
    MARCHAL, G
    [J]. RADIOLOGY, 1992, 185 (01) : 29 - 35
  • [7] 3-DIMENSIONAL SPIRAL COMPUTED TOMOGRAPHIC ANGIOGRAPHY - AN ALTERNATIVE IMAGING MODALITY FOR THE ABDOMINAL-AORTA AND ITS BRANCHES
    RUBIN, GD
    WALKER, PJ
    DAKE, MD
    NAPEL, S
    JEFFREY, RB
    MCDONNELL, CH
    MITCHELL, RS
    MILLER, DC
    [J]. JOURNAL OF VASCULAR SURGERY, 1993, 18 (04) : 656 - 665
  • [8] 3-DIMENSIONAL SPIRAL CT ANGIOGRAPHY OF THE ABDOMEN - INITIAL CLINICAL-EXPERIENCE
    RUBIN, GD
    DAKE, MD
    NAPEL, SA
    MCDONNELL, CH
    JEFFREY, RB
    [J]. RADIOLOGY, 1993, 186 (01) : 147 - 152
  • [9] SPIRAL CT OF RENAL-ARTERY STENOSIS - COMPARISON OF 3-DIMENSIONAL RENDERING TECHNIQUES
    RUBIN, GD
    DAKE, MD
    NAPEL, S
    JEFFREY, RB
    MCDONNELL, CH
    SOMMER, FG
    WEXLER, L
    WILLIAMS, DM
    [J]. RADIOLOGY, 1994, 190 (01) : 181 - 189
  • [10] ROLE OF MR-IMAGING IN THE PREOPERATIVE EVALUATION OF ATHEROSCLEROTIC ABDOMINAL AORTIC-ANEURYSMS
    SALLEVELT, PEJM
    BARENTSZ, JO
    RUIJS, SJHJ
    HEIJSTRATEN, FMJ
    BUSKENS, FGM
    STRIJK, SP
    [J]. RADIOGRAPHICS, 1994, 14 (01) : 87 - 98