PHASE-AMPLITUDE RESETTING OF THE HUMAN CIRCADIAN PACEMAKER VIA BRIGHT LIGHT - A FURTHER ANALYSIS

被引:105
作者
JEWETT, ME [1 ]
KRONAUER, RE [1 ]
CZEISLER, CA [1 ]
机构
[1] HARVARD UNIV,BRIGHAM & WOMENS HOSP,SCH MED,DEPT MED,DIV ENDOCRINOL,BOSTON,MA 02115
关键词
CIRCADIAN; PHASE SHIFTS; TYPE; 1; RESETTING; 0; PHASE RESPONSE CURVE; MODELS; AMPLITUDE; LIGHT; HUMAN;
D O I
10.1177/074873049400900310
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We present here an analysis of strong, weak, and critical bright-light resetting trials in humans, and report not only phase but also amplitude data for the first time. For this analysis, an appropriate iterative smoothing procedure for phase transition curves is introduced, in which the data are sequenced so as to minimize the perpendicular distance from the data to the smoothed fit. From these smoothed data, we create polar phase-amplitude resetting-maps.(PARMs) in order to fully. illustrate the effects of the resetting stimuli on both circadian amplitude and phase, and thereby to determine whether these resetting results can be decribed by a phase-only model or whether a phase-amplitude model is required. Our results indicate that a single 5-hr episode of bright light induces weak type 1 resetting of the human circadian pacemaker. Two cycles of exposure to the same stimulus on consecutive days induce critical resetting, in which significant amplitude reduction may be observed. A three-cycle stimulus induces strong type 0 resetting-with different effects-on circadian amplitude, depending on the initial phase of the stimulus application. When a three-cycle stimulus is centered near the nadir of the temperature cycle, large phase shifts are achieved via amplitude suppression. However, when this stimulus is centered away from the temperature nadir, smaller phase shifts are achieved in which both small increases and small decreases in circadian amplitude are observed. These data indicate that the human circadian pacemaker is not a simple, phase-only oscillator. Instead, a full description of human circadian resetting responses to light requires analysis of both phase and amplitude data-a finding that is consistent with a phase-amplitude model of the circadian resetting mechanism.
引用
收藏
页码:295 / 314
页数:20
相关论文
共 42 条
  • [1] [Anonymous], 2014, VIRTUES HAPPINESS TH, DOI DOI 10.1093/ACPROF:OSO/9780199827367.001.0001
  • [2] BEERSMA DGM, 1993, J BIOL RHYTHM, V8, P340, DOI 10.1177/074873049300800407
  • [3] BEERSMA DGM, 1993, REPLY J BIOL RHYTHMS, V8, P361
  • [4] THE STATISTICAL-ANALYSIS OF CIRCADIAN PHASE AND AMPLITUDE IN CONSTANT-ROUTINE CORE-TEMPERATURE DATA
    BROWN, EN
    CZEISLER, CA
    [J]. JOURNAL OF BIOLOGICAL RHYTHMS, 1992, 7 (03) : 177 - 202
  • [5] EARLY MORNING BRIGHT LIGHT PHASE ADVANCES THE HUMAN CIRCADIAN PACEMAKER WITHIN ONE DAY
    BURESOVA, M
    DVORAKOVA, M
    ZVOLSKY, P
    ILLNEROVA, H
    [J]. NEUROSCIENCE LETTERS, 1991, 121 (1-2) : 47 - 50
  • [6] CAMPBELL SS, 1993, SLEEP, V16, P638
  • [7] CHANDRASHEKARAN M K, 1976, International Journal of Chronobiology, V3, P231
  • [8] Czeisler C. A., 1990, HDB SLEEP DISORDERS, P117
  • [9] Czeisler C.A., 1990, SLEEP BIOL RHYTHMS B, P87
  • [10] ASSOCIATION OF SLEEP-WAKE HABITS IN OLDER-PEOPLE WITH CHANGES IN OUTPUT OF CIRCADIAN PACEMAKER
    CZEISLER, CA
    DUMONT, M
    DUFFY, JF
    STEINBERG, JD
    RICHARDSON, GS
    BROWN, EN
    SANCHEZ, R
    RIOS, CD
    RONDA, JM
    [J]. LANCET, 1992, 340 (8825) : 933 - 936